Service and Repair Manual
March 2021
Battery Charger
182
GS
™
-30 • 32 • 46 • 47
Part No. 1272217GT
Charger Error Codes
Error Code
Description
Condition
Possible Causes
E-0-0-8
Battery temperature out of range
Battery temperature sensor.
Check temperature sensor and
electrical connections.
Rest charger. Disconnect AC
power for 30 seconds.
Self clearing when condition has
been corrected.
E-0-1-1
Charger disabled by external command
Battery pack not being charged..
Power outage.
AC power disconnected before
charging complete.
E-0-1-2
Reverse polarity
Battery connected incorrectly.
Check battery connections.
Self clearing when condition has
been corrected.
E-0-1-3
Battery does not take current
Battery voltage is detected, but
charger is unable to charge the
battery pack..
Incorrect profile for battery type.
Installed from a different machine
with different battery type.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
E-0-1-6
Software update failed
Software update failed.
Confirm USB Flash Drive is
formatted with correct software.
If software update continues to
fail, contact Genie Product
support.
E-0-1-7
USB error
USB not connected correctly.
Remove and re-insert USB Flash
Drive.
Disconnect AC input and battery
pack for 30 seconds.
E-0-1-8
Slot CRC error
Software update failed.
Confirm USB Flash Drive is
formatted with correct software.
If software update continues to
fail, contact Genie Product
support.
E-0-1-9
Hardware does not support software
Charger hardware does not support
software version being
programmed.
Confirm USB Flash Drive is
formatted with correct software.
If software update continues to
fail, contact Genie Product
support.
E-0-2-0
No algorithm selected
Charger profile not programmed.
Program the charger for the
proper battery profile.