May 2015
Service Manual
Fault Codes
Part No. 1257106
GS-2669 BE • GS-3369 BE • GS-4069 BE
133
1 Disconnect the GCON ECM connectors, C1, C2 and C3.
(or C4 if equipped with outriggers).
2 For short to B- type faults, measure resistance between
pins J1-7 (ground) and the GCON pin associated with the
fault code. Refer to the GCON I/O Map in this section to
identify the faulted out circuit pin.
3 Short to ground resistance should be greater than 5k
Ω
.
4 For short to B+ type faults, measure resistance between
pins J1-12 (driver power) and the GCON pin associated
with the fault code. Refer to the GCON I/O Map in this
section to identify the faulted out circuit pin.
5 Short to power resistance should be greater than 50k
Ω
.
No Good
Replace GCON ECM
Summary of Contents for Genie GS-2669 BE
Page 1: ...Service Manual GS 2669 BE GS 3369 BE GS 4069 BE Part No 1257106 Rev A3 May 2015...
Page 27: ...May 2015 Service Manual Specifications Part No 1257106 GS 2669 BE GS 3369 BE GS 4069 BE 11...
Page 100: ...Service Manual May 2015 Manifolds 84 GS 2669 BE GS 3369 BE GS 4069 BE Part No 1257106...
Page 173: ...May 2015 Service Manual 157 Contactor Box Layout All Models...
Page 176: ...Service Manual May 2015 160 Ground Control Box Layout All Models...
Page 177: ...May 2015 Service Manual 161 Platform Control Box Layout All Models...
Page 180: ...Service Manual May 2015 164 Generator Wiring Diagram All Models...
Page 185: ...May 2015 Service Manual 169 Electrical Schematic GS 4069 BE with 2 Speed Lift ANSI CSA...
Page 188: ...Service Manual May 2015 172 Electrical Schematic GS 4069 BE with Proportional Lift ANSI CSA...
Page 193: ...May 2015 Service Manual 177 Electrical Schematic GS 4069 BE with 2 Speed Lift AS CE...
Page 196: ...Service Manual May 2015 180 Electrical Schematic GS 4069 BE with Proportional Lift AS CE...
Page 197: ...May 2015 Service Manual 181 Hydraulic Schematic GS 2669 BE and GS 3369 BE with 2 Speed Lift...
Page 201: ...May 2015 Service Manual 185 Hydraulic Schematic GS 4069 BE with 2 Speed Lift...
Page 205: ......