Maintenance
Fuel
Refuel through cap
A
. Use only Diesel fuel with
less than 0.5% sulphur content, according to
the specifications of the diesel engine operation
handbook.
NOTICE
In cold climates (temperature under -20°C) use
only Arctic type Diesel fuel, or oil-diesel fuel,
or oil-diesel fuel mixtures. The composition
of the latter can vary in relation to the ambient
temperature up to max. 80% oil.
Grease
For the machine greasing, use:
NOTICE
Avoid mixing greases of different type or features
and do not use greases of lower quality.
Engine coolant
It is advisable to use an antifreeze mixture (50%
water-50% antifreeze). At the delivery, the machine
is refilled with:
TEREX PRO COOL by VALVOLINE
The use of this product guarantees protection to the
circuit for 3 years or 7000 hours without having to
add any dry coolant additive.
NOTICE
Use an antifreeze mixture in the proportions
recommended by the manufacturer in relation to
the ambient temperature of the jobsite.
Lithium-based
Vanguard LIKO
grease, type EP2
When greasing by
pump.
Graphitized AGIP
grease, type GR NG 3
When greasing by
brush.
INTERFLON FIN
GREASE LS 2
On the telescopic
boom
TEREX PRO COOL
Protection against boiling / freezing
Product %
Freezing point
Boiling point
33
40
50
70
-17°C
-24°C
-36°C
-67°C
123°C
126°C
128°C
135°C
112 GTH-4518ER - GTH-4020ER - GTH-6025ER Part No. 57.0009.0404
Operator’s Manual
First Edition - Third Printing
Summary of Contents for Genie GTH-4020 ER