Controls And Instruments
MO
1
19
18
22
23
Safety and Emergency Devices
22 _ Emergency Stop Pushbutton
By pressing this button, the engine of the machine
is shut down.
Before restarting the machine, it is necessary to reset
the pushbutton by rotating it clockwise.
23 _ Load Limiter Disable Selector
The load limiter can be deactivated operating the
key-selector placed under the protection cover.
DANGER
WORKING WITH THE LOAD LIMITING SYSTEM CUT OUT CAN
RESULT IN A MACHINE OVERTURNING AND IN SERIOUS
INJURY.
18 _ Hazard Warning Lights Switch
Fitted with on-off position, it switches on the turn
signals simultaneously. When the hazard warning
light is lit, the relevant switch and the turn signals
light start flashing.
19 _ Emergency Pump Control
It
is located on the left side of the dashboard and has
two positions with automatic return to centre.
When the button is held pressed down, the emergency
pump is activated. Releasing the button stops the
pump.
The activation of the emergency pump should be done
with the simultaneous operation of the cab controls
or the main valve manual controls.
Correct operation sequence:
• Turn the ignition key
20
to position
I
.
• Shift the control lever to the desired position.
• Press the emergency pump control button
19
.
Do not start the emergency pump before shifting
the control lever. The emergency pump is driven
by an electric motor. Therefore, it is advisable to
let the motor run for about 30 seconds, then stop
for about 2 minutes to let the motor cool down.
NOTICE
Check the operation of the emergency pump every
week as it could get damaged if it is not used.
30 GTH-4518ER - GTH-4020ER - GTH-6025ER Part No. 57.0009.0404
Operator’s Manual
First Edition - Third Printing