Maintenance
OIL LEVEL IN THE POWER DIVIDER
GEARBOX
To check the oil level in the power diver gearbox:
• Stop the machine on a level ground and make
sure the parking brake is engaged.
• Clean level plug
all around.
• Remove the plug and check if oil is level with the
hole.
• When necessary, add new oil through plug
until it is level with the hole.
• Refit and tighten the plug.
To change the oil:
• Place a container of suitable size under the drain
plug.
• Remove the plug
.
• Remove the drain plug
and empty the power
divider gearbox.
• Refit and tighten the drain plug
.
• Pour in new oil through the filler
placed at
the top of the reduction gear of the power divider.
Stop when oil is level with hole
.
• Refit and tighten plug
.
SERVICE INTERVAL
Running-in
_________ Within the first
10
hours
Ordinary _________________
Every
250
hours
Filling plug
Drain plug
Part No. 57.0009.0404 GTH-4518ER - GTH-4020ER - GTH-6025ER 93