Maintenance
1÷2 mm
SERVICE INTERVAL
Running-in
_________________________
None
Ordinary
_________________
When necessary
ADJUSTING THE SENSOR DISTANCE
In case of a failure or complete malfunctioning of the
sensors due to a loosening of their fixing ring nuts,
re-adjust their position:
1
Loosen
nuts
A
fixing sensor
B
.
2
Set the mobile part
C
of the machine, controlled
by the sensor, as close as possible to it.
Near the sensor to the component until the LED
indicator
D
lights up.
3
Further near the sensor by 1÷2 mm.
Smoothly tighten the sensor fixing nut and the
relevant lock nut.
The machine is fitted with the following proximity
switches:
E N° 1 turntable unlocking cylinder sensor
F N° 1 turntable rotation locking sensor.
G N° 1 turntable alignment sensor.
Part No. 57.0009.0404 GTH-4518ER - GTH-4020ER - GTH-6025ER 99