82 GTH-4016SR • GTH-4018SR Part No. 57.4400.9203
March 2010
Section 6 • Troubleshooting
REV A
TROUBLESHOOTING
Overload Warning System Fault
Codes
1. CAN ERROR
display unit does not receive correct CAN messages
or does not receive at all CAN messages from Control
unit or Platform unit in case platform is selected,
telehandler can not work
2. LOAD TABLE ERROR
load table data read from EEPROM are corrupted
then telehandler can not work
3. MACHINE DATA ERROR
telehandler data read from EEPROM are corrupted
then telehandler can not work
4. CB0 TABLE ERROR
Cb0 table data read from EEPROM are corrupted
then telehandler can not work
5. ERR LEN SENS 1 VBAT / ERR LEN SENS 2
VBAT
Length sensor 1 or 2 signal is larger than MAX1/MIN2
stored value then telehandler can not work. Sensor
has not yet been calibrated or potentiometer is broken
or wire is connected to +5Vdc or +12Vdc voltage
6. ERR LEN SENS 1 OPEN / ERR LEN SENS 2
OPEN
Length sensor 1 or 2 signal is less than MIN1 stored
value then telehandler can not work. Sensor has not
yet been calibrated or potentiometer is broken or wire
is connected to ground or wire cut or sensor is not
correctly connected to power supply
7. ERR LEN SENS DIFF
Length sensor 1 and 2 does not give the same length
value then telehandler can not work. Sensor has not
yet been calibrated or potentiometers are broken or
there is some wire wrong connections
8. ERR ANG SENS 1 VBAT / ERR ANG SENS 2
VBAT
Angle sensor 1 or 2 signal is larger than maximum
possible (4.5V or 920 BIT) then telehandler can
not work. Sensor is broken or wire is connected to
+5Vdc or +12Vdc voltage or sensor is not correctly
connected to power supply
9. ERR ANG SENS 1 OPEN / ERR ANG SENS 2
OPEN
Angle sensor 1 or 2 signal is less than minimum
possible (0.5V or 102 BIT) then telehandler can not
work. Sensor is broken or wire is connected to ground
or wire is cut or sensor is not correctly connected to
power supply
10. ERR ANG SENS DIFF
Angle sensor 1 and 2 does not give the same angle
value then telehandler can not work. Sensor are
broken or there is some wires wrong connection
11. ERR SENS PSP VBAT / ERR SENS PSR VBAT /
ERR SENS PEP VBAT / ERR SENS PER VBAT
Pressure sensor signal is larger than maximum
possible (4.5V or 920 BIT) then telehandler can
not work. Sensor is broken or wire is connected to
+5Vdc or +12Vdc voltage or sensor is not correctly
connected to power supply
12. ERR SENS PSP OPEN / ERR SENS PSR OPEN /
ERR SENS PEP OPEN / ERR SENS PER OPEN
Pressure sensor signal is less than minimum possible
(0.5V or 102 BIT) then telehandler can not work.
Sensor is broken or wire is connected to ground or
wire is cut or sensor is not correctly connected to
power supply
13. ONLY IMPLEMENTS
Platform/Road/Jobsite switch is on Jobsite position
but a platform is selected therefore telehandler can
not work