Sixth Edition • First Printing
Operator's Manual
Inspections
Part No. 1298036GT
IWP
®
Super Series
23
Function Tests
Setup
1
Select a test area that is firm, level and free of
hazards.
2
Pump the foot pedal
to raise the base.
Result: The wheels
should contact the
ground.
3
Pull the base lowering
handle to fully lower
the base.
Result: All four foot
pads should come in
firm contact with the
ground.
4
Connect to the appropriate power source.
5
Use the bubble level and adjust the leveling
jacks until the machine is level and all four foot
pads are in firm contact with the ground.
6
Insert the key and turn to platform control.
7
Pull out the red Emergency Stop button at the
ground controls to the on position.
8
Pull out the platform red Emergency Stop
button to the on position.
Result: The power light should come on.
Within 1 to 4 seconds, the two level sensor
interlock display lights and the two foot pad
interlock display lights should turn on and
remain on.
Note: Two different interlock display decals were
produced. The symbols on them are different but
they both operate the same way. Both are
illustrated here and in the text throughout this
manual.
Test Interlock System
9
Pump the foot pedal to raise the base.
Result: The two footpad display lights should
be off.