Operator's Manual
Sixth Edition • First Printing
Inspections
24
IWP
®
Super Series
Part No. 1298036GT
10
Pull the base lowering handle to fully lower the
base.
Result: The two footpad display lights should
be on.
11
Pump the foot pedal to raise the base.
12
Turn both the leveling jacks clockwise to the
full down position.
13
Pull the base lowering handle to fully lower the
base.
Result: The base will lower and the two level
sensor display lights should be off and remain
off because the base is not level.
14
At the platform controls, push in the control
activate button and rotate the up/down switch
to the up position, then the down position.
Result: The platform up/down function should
not operate.
Test Emergency Stop
15
Use the bubble level and adjust the leveling
jacks until the machine base is level. Be sure
all four display lights at the ground controls are
on.
16
Push in the ground red Emergency Stop
button to the off position.
17
Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up/down function should not
operate.
18
Push in the platform red Emergency Stop
button to the off position.
19
Pull out the red Emergency Stop button at the
ground controls to the on position.
20
Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up/down function should not
operate.
Summary of Contents for Genie IWP Series