Operator's Manual Supplement
First Edition • Second Printing
Software Update
18 Lift
Guard
™
Contact Alarm
Part No. 1288739GT
Firmware Site Download
Note: Access to the internet is required to
perform this procedure.
1
Click on the Hyperlink below or open an
internet browser and copy and paste or type
the link into the address bar and press enter.
http://firmware.genielift.com
2
Select
Machine Model.
Select
Search.
3
Under
Application Firmware
, select the
Firmware File
for
PROP LIFT
and save it to
your desktop.
4
Locate and open the file saved on your
desktop.
5
Right click on the
.zip
file and select
extract
all
.
Note: Verify the
Show extracted files when
complete
box is checked.
6
Select and open instructions
216767
under
Application Firmware
.
7
Refer to Machine Application Mode procedure
to complete the software upgrade.
8
Download the
Instructions
and follow the
procedures to update the machine software.
Note: After the control system software has been
updated, the contact alarm option must be
activated at the ground controls to function
properly. Refer to Activating or Deactivating the
Contact Alarm.
Activating or Deactivating the
Contact Alarm
Note: The contact alarm must be activated in the
options menu for the machine to function properly
when it has been installed on the machine.
Note: The contact alarm must be deactivated in the
options menu for the machine to function properly
when it has been removed from the machine.
1
Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at the platform
controls.
2
Press and hold the ground control scroll up and
scroll down buttons.
1
scroll down button
2
enter button
3
scroll up button
4
escape button
5
LCD display
137562
4
3
2
1
1
5
3
2
4
Summary of Contents for Genie Lift Guard GS-4047