October 2018
Service and Repair Manual
Limit Switches and Angle Sensors
Part No. 1268557GT
Z®-135
/70
203
Rotary Sensor Numbering
RSP1AO
Primary boom angle sensor
RSP1AS
Primary boom angle sensor, safety
RSJ1AO
Jib boom angle sensor
RSS1AO
Secondary boom angle sensor
RSS1AS
Secondary boom angle sensor, safety
RSFA1O
Front axle postioning sensor
RSRA1O
Rear axle positioning sensor
RSLF1SO
Left front wheel positioning sensor
RSRF1SO
Right front wheel positioning sensor
RSLR1SO
Left rear wheel positioning sensor
RSRR1SO
Right rear wheel positioning sensor
Limit Switch Functions
Platform Angle Sensor:
Measures the angle of
the platform. The range of measurement is +/-
20 degrees. The safety cutout is set at +/-
10 degrees from gravity and will disable the primary
and secondary boom up/down functions and the
platform level up/down functions.
Jib Bell Crank Angle Sensor:
Measures the angle
of the jib bell crank. The range of measurement is +
60 / -70 degrees.
Safety Controller (SCON):
Redundant dual axis
tilt sensors measuring the X and Y tilt angles of the
turntable. Also provides safety switch logic for
function cut-off. Alarm sounds at ±4.5 degrees.
LSFA1ES:
Limit switch, Front Axle #1 Extended
Safety. Prevents boom functions with the axles
retracted. Switch closes when axles are fully
extended.
LSRA1ES:
Limit switch, Rear Axle #1 Extended
Safety. Prevents boom functions with the axles
retracted. Switch closes when axles are fully
extended.
LST1O:
Limit switch, Turntable #1 Operational.
Activates the drive enable zone when the turntable
is rotated in the left direction.
LST2O:
Limit switch, Turntable #2 Operational.
Activates the drive enable zone when the turntable
is rotated in the right direction.
LST1S:
Limit switch, Turntable #1 Safety. Prevents
the turntable from rotating out past either rear tire
when axles are retracted.
LSS1RO:
Limit switch, Secondary Boom #1
Retracted Operational. NOHC when secondary
boom is fully retracted. Used to reduce turntable
rotate speed when secondary boom is extended
and to disable secondary boom down unitl fully
retracted.
LSS1RS:
Limit switch, Secondary Boom #1 Retract
Safety Switch. Backup switch for LSS1RO. Used to
cut circuits P9B, P_11 and P_30.
LSJ1RO:
Limit Switch, Jib Boom #1 Retract
Operational. Switch is held closed when the jib
boom fully retracted. Used to limit turntable rotate
speed and drive speed when jib boom is extended.
LSP1EO:
Limit Switch, Primary Boom #1 Extend
Operational. Switch closes when the primary boom
is fully extended. NOHC when fully extended.
LSP1RO:
Limit Switch, Primary Boom #1 Retract
Operational. Switch closes when the primary boom
is retracted. NOHC when fully retracted
Summary of Contents for Genie Z-135/70
Page 14: ......
Page 37: ...October 2018 Service and Repair Manual Specifications Part No 1268557GT Z 135 70 23 T ...
Page 135: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 121 ...
Page 137: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 123 ...
Page 139: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 125 ...
Page 141: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 127 ...
Page 147: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 133 ...
Page 153: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 139 ...
Page 155: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 141 ...
Page 159: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 145 ...
Page 161: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 147 ...
Page 233: ...October 2018 Service and Repair Manual 219 Generator Wiring Schematic ...
Page 236: ...Service and Repair Manual October 2018 222 Hydraulic Generator Welder Option ...
Page 242: ...Service and Repair Manual October 2018 228 Hydraulic Schematic from serial number 535 ...
Page 244: ......