Operator's Manual
Seventh Edition • First Printing
Operating Instructions
40
Z
®
-
34/22N • Z
®
-34/22DC
Part No. 1297937GT
Drive Enable
Light on indicates that the boom
has moved just past either
non-steer wheel and the drive
function has been interrupted.
To drive, hold the drive enable switch up or down
and slowly move the drive control handle off center.
Be aware that the machine may move in the
opposite direction that the drive and steer controls
are moved.
Always use the color-coded direction arrows on the
platform controls and the drive chassis to identify
the direction the machine will travel.
Low Voltage Interrupt (if equipped)
Machines equipped with Low Voltage Interrupt will
lose primary and secondary boom up functions
from the platform when batteries are low.
Machine Not Level Indicator Light
If the tilt alarm sounds when the
platform is raised, use extreme
caution. The machine not level
indicator light will come on and the
drive function in one or both
directions will not operate. Identify
the condition of the boom on the
slope as shown below. Follow the
steps to lower the boom before
moving to a firm, level surface. Do
not rotate the boom while lowering.
If the tilt alarm sounds with
the platform uphill:
1
Lower the primary
boom.
2
Lower the secondary
boom.
3
Retract the primary
boom.
If the tilt alarm sounds with
the platform downhill:
1
Retract the primary
boom.
2
Lower the secondary
boom.
3
Lower the primary
boom.
Summary of Contents for Genie Z-34/22DC