Service and Repair Manual
September 2016
Specifications
4
Z-40/23N, Z-40/23N RJ
Part No. 1268528
Chevron Rando HD Premium Oil
MV Fluid Properties
ISO Grade
32
Viscosity index
200
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
7.5
33.5
Brookfield Viscosity
cP @ -4°F / -20°C
cP @ -22°F / -30°C
1040
3310
Flash point
375°F / 190°C
Pour point
-58°F / -50°C
Maximum continuous operating
temperature
171°F / 77°C
Note: A hydraulic oil heating system is
recommended when the ambient temperature is
consistently below 0°F / -18°C.
Note: Do not operate the machine when the
ambient temperature is below -20°F / -29°C with
Rando HD Premium MV.
Chevron 5606A Hydraulic Oil
Fluid Properties
ISO Grade
15
Viscosity index
300
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
cSt @ -40°F / -40°C
5.5
15.0
510
Flash point
180°F / 82°C
Pour point
-81°F / -63°C
Maximum continuous operating
temperature
124°F / 51°C
Note: Use of Chevron 5606A hydraulic fluid, or
equivalent, is required when ambient temperatures
are consistently below 0°F / -17°C unless an oil
heating system is used.
Continued use of Chevron 5606A
hydraulic fluid, or equivalent,
when ambient temperatures are
consistently above 32°F / 0°C
may result in component damage
Petro-Canada Environ MV 46
Fluid Properties
ISO Grade
46
Viscosity index
154
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
8.0
44.4
Flash point
482°F / 250°C
Pour point
-49°F / -45°C
Maximum continuous operating
temperature
180°F / 82°C
Shell Tellus S4 VX Fluid
Properties
ISO Grade
32
Viscosity index
300
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
9
33.8
Brookfield Viscosity
cSt @ -4°F / -20°C
cSt @ -13°F / -25°C
cSt @ -40°F / -40°C
481
702.4
2624
Flash point
>100
Pour point
-76°F / -60°C
Maximum continuous operating
temperature
103°F / 75°C
UCON Hydrolube HP-5046 Fluid
Properties
ISO Grade
46
Viscosity index
192
Kinematic Viscosity
cSt @ 149°F / 65°C
cSt @ 104°F / 40°C
cSt @ 0°F / -18°C
22
46
1300
Flash point
None
Pour point
-81°F / -63°C
Maximum continuous operating
temperature
189°F / 87°C
Summary of Contents for Genie Z-40/23N
Page 63: ...September 2016 Service and Repair Manual Manifolds Part No 1268528 Z 40 23N Z 40 23N RJ 53 ...
Page 111: ...September 2016 Service and Repair Manual 101 Electrical Schematic Chassis ...
Page 114: ...Service and Repair Manual September 2016 104 Electrical Schematic Ground Controls ...
Page 115: ...September 2016 Service and Repair Manual 105 Electrical Schematic Platform Controls ...
Page 118: ...Service and Repair Manual September 2016 108 Ground Control Box Wiring Diagram ...
Page 119: ...September 2016 Service and Repair Manual 109 Platform Control Box Wiring Diagram ...
Page 122: ...Service and Repair Manual September 2016 112 Platform Control Box Wiring Diagram Options ...
Page 123: ...September 2016 Service and Repair Manual 113 Hydraulic Schematic ...
Page 125: ......