Service and Repair Manual
September 2016
Platform Controls
16
Z-40/23N, Z-40/23N RJ
Part No. 1268528
13 Release the footswitch. Momentarily activate
the steer rocker in the left direction to
decrease the value shown on the display in
small increments. Continue to step 14.
14 Press down on the foot switch and activate the
same function in the same direction. Repeat
step 13 until the alarm sounds while function is
in motion. Then release the foot switch and
momentarily activate the steer rocker switch in
the right direction 3 times. Continue to step 17.
15 Release the footswitch. Momentarily activate
the steer rocker in the right direction to
increase the value shown on the display in
small increments. Continue to step 16.
16 Press down on the foot switch and activate the
same function in the same direction. Repeat
step 15 until the alarm no longer sounds while
function is in motion. Then momentarily
activate the steer rocker switch in the right
direction 2 times. Continue to step 17.
17 Momentarily activate the drive enable toggle
switch in the right direction to save the new
setting.
Result: The alarm should sound indicating the
setting has been saved.
18 Repeat steps 11 through 17 as needed for
high flow functions.
Low flow functions:
19 Momentarily activate one of the low flow
functions full stroke.
Result: The display will show the function,
direction and milliamps.
20 Start a timer, press down on the foot switch
and activate the same function in the same
direction again.. Record the time it takes for
that function to complete a full cycle; i.e., jib
up.
21 Compare the machine function time with the
function times listed. Refer to Specifications
,
Performance Specifications.
Determine
whether the function time needs to increase or
decrease.
22 To adjust a function speed, release the foot
switch. Momentarily move the steer rocker
switch in the right direction to increase or
momentarily in the left direction to decrease.
Note: Each time the steer rocker switch is
momentarily pressed, the time will change in 5mA
to 10mA increments.
23 When function times have been achieved,
activate the drive enable toggle switch to the
right to save your changes.
Result: The alarm should sound indicating the
setting has been saved.
24 Repeat steps 19 through 23 as needed for low
flow functions.
To exit programming mode:
25 Move and hold the drive enable toggle switch
in the left direction until the display screen
returns to SYSTEM READY.
Summary of Contents for Genie Z-40/23N
Page 63: ...September 2016 Service and Repair Manual Manifolds Part No 1268528 Z 40 23N Z 40 23N RJ 53 ...
Page 111: ...September 2016 Service and Repair Manual 101 Electrical Schematic Chassis ...
Page 114: ...Service and Repair Manual September 2016 104 Electrical Schematic Ground Controls ...
Page 115: ...September 2016 Service and Repair Manual 105 Electrical Schematic Platform Controls ...
Page 118: ...Service and Repair Manual September 2016 108 Ground Control Box Wiring Diagram ...
Page 119: ...September 2016 Service and Repair Manual 109 Platform Control Box Wiring Diagram ...
Page 122: ...Service and Repair Manual September 2016 112 Platform Control Box Wiring Diagram Options ...
Page 123: ...September 2016 Service and Repair Manual 113 Hydraulic Schematic ...
Page 125: ......