Service and Repair Manual
September 2016
Control System Fault Codes
74
Z-40/23N, Z-40/23N RJ
Part No. 1268528
Error Source
Error Type
ID Name
ID Name
Condition
Solution
33
SEC_DN_VALVE
Secondary boom
down valve.
12
15
Value too high
Value too low
Secondary down function
disabled.
Check for open or short from TCON
(C14-8) to the secondary down coil.
Replace coil.
36
JIB_UP_VALVE
Jib boom up valve.
12
15
Value too high
Value too low
Jib up function disabled.
Check for open or short from PCON
(C29-5) to the jib up coil. Replace
coil.
37
JIB_DN_VALVE
Jib boom down
valve.
12
15
Value too high
Value too low
Jib down function
disabled.
Check for open or short from PCON
(C29-6) to the jib down coil. Replace
coil.
41
TT_ROT_JYSTK
Turntable rotate
joystick.
11
16
Shorted to supply
Value at 0V
Turntable rotate
functions disabled.
Inspect and repair joystick wiring.
Replace joystick.
17
Not calibrated
Neutral out of range
Turntable rotate
functions disabled.
Check neutral output range is within
2000 to 3000 mV. Calibrate joystick.
Replace joystick.
42
TT_CW_VALVE
Turntable rotate
clockwise valve.
12
15
Value too high
Value too low
Turntable rotate
clockwise function
disabled.
Check for open or short from TCON
(C29-8) to the turntable CW coil.
Replace coil.
43
TT_CCW_VALVE
Turntable rotate
counter clockwise
12
15
Value too high
Value too low
Turntable rotate
counterclockwise
function disabled.
Check for open or short from TCON
(C29-7) to the turntable CCW coil.
Replace coil.
46
PROT_CW_VALV
Platform rotate
clockwise valve.
12
15
Value too high
Value too low
Platform rotate clockwise
function disabled.
Check for open or short from PCON
(C29-3) to the platform rotate CW
coil. Replace coil.
47
PROT_CCW_VLV
Platform rotate
counter clockwise
12
15
Value too high
Value too low
Platform rotate
counterclockwise
function disabled.
Check for open or short from PCON
(C29-4) to the platform rotate CCW
coil. Replace coil.
51
DRIVE_JYSTK
Drive joystick.
11
16
Shorted to supply
Value at 0V
Drive functions disabled.
Inspect and repair joystick wiring.
Replace joystick.
17
Not calibrated
Neutral out of range
Check neutral output range is within
2000 to 3000 mV. Calibrate joystick.
Replace joystick.
Summary of Contents for Genie Z-40/23N
Page 63: ...September 2016 Service and Repair Manual Manifolds Part No 1268528 Z 40 23N Z 40 23N RJ 53 ...
Page 111: ...September 2016 Service and Repair Manual 101 Electrical Schematic Chassis ...
Page 114: ...Service and Repair Manual September 2016 104 Electrical Schematic Ground Controls ...
Page 115: ...September 2016 Service and Repair Manual 105 Electrical Schematic Platform Controls ...
Page 118: ...Service and Repair Manual September 2016 108 Ground Control Box Wiring Diagram ...
Page 119: ...September 2016 Service and Repair Manual 109 Platform Control Box Wiring Diagram ...
Page 122: ...Service and Repair Manual September 2016 112 Platform Control Box Wiring Diagram Options ...
Page 123: ...September 2016 Service and Repair Manual 113 Hydraulic Schematic ...
Page 125: ......