Boom angle sensors are installed on the primary
and secondary boom sections. They are used
to detect whether the boom sections are stowed
or not stowed. A two point calibration procedure
captures the signal with the cylinder fully extended
and fully retracted to an angle measurement that
is scaled to degrees within the program. If either
angle sensor is in the uncalibrated state, drive
speed is limited to out-of-stowed speed.
Note: Start this procedure with the boom in a
stowed position. Position the machine in a suitable
location with sufficient vertical space. Refer to
Navigation Menus, Settings Menu.
1 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
2 Move and hold the drive enable toggle switch
in the right direction while holding steer in the
right direction.
3 When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer joystick.
Result: The display will show
FAULTS
.
4 Momentarily activate steer in the right direction
until SETTINGS is shown on the display.
5 Momentarily activate the drive enable toggle
switch in the right direction until you see the
VALVE AND SENSOR SETTINGS screen.
6 Momentarily activate the drive enable toggle
switch in the right direction until you see the
CALIBRATE TILT SENSOR screen.
7 Momentarily activate steer in the right direction
until BOOM ANGLE CALIBRATE is shown on
the display.
8 Momentarily activate the drive enable toggle
switch in the right direction to enter the BOOM
ANGLE CALIBRATE screen.
9 Momentarily activate the drive enable toggle
switch in the right direction to enter the sub-
menu.
Result: The screen will display PRI SNSR
MVXXXX, SEC SNSR MVXXXX. A flashing
value indicates the mV (millivolt) value is within
expected range.
10 Momentarily activate the drive enable toggle
switch in the right direction to store the millivolt
value.
Result: An alarm will sound for one second and
the screen will display CALIBRATED.
11 Calibrate the boom elevated positions, fully
raise the primary and secondary booms.
Repeat steps 9 and 10 to store the millivolt
value.
Result: An alarm will sound for two seconds
and the screen will display CALIBRATED
indicating both the primary and secondary
angle sensors have been calibrated
successfully.
To exit programming mode:
12 Move and hold the drive enable toggle in the
left position until the display returns to SYSTEM
READY mode.
Platform Controls
Summary of Contents for Genie Z-45 DC
Page 121: ...July 2020 Service and Repair Manual 111 Wiring Diagram Options ...
Page 124: ...July 2020 Service and Repair Manual 114 Wiring Diagram Options ...
Page 125: ...July 2020 Service and Repair Manual 115 Schematics Options DC and FE Models ...
Page 127: ...July 2020 Service and Repair Manual 117 Power Cable Wiring Diagram ...
Page 129: ...July 2020 Service and Repair Manual 119 Hydraulic Schematic ...
Page 131: ...July 2020 Service and Repair Manual 121 Electrical Schematic DC FE Models ...
Page 134: ...July 2020 Service and Repair Manual 124 Electrical Schematic DC FE Models ...
Page 136: ...July 2020 Service and Repair Manual 126 Electrical Schematic DC FE Models ...