88
Z
®
-45 DC • Z
®
-45 FE
Part No. 1297714GT
July 2020
Service and Repair Manual
Control System Fault Codes
Error Source
Error Type
Cause
Effect
Solution
ID
Component
ID
Name
140
Pump &
Drive Controllers:
136=Pump[ECON]
137=Left Front[LF]
138=Right Front[RF]
139=Left Rear[LR]
140=Right Rear[RR]
(continued)
29
Motor Temp Sensor Fault
1. Motor thermistor is not connected
properly.
2. If the application doesn’t use a motor
thermistor, Motor Temp Sensor Enable
should be programmed Off.
MaxSpeed reduced
(LOS,
Limited Operating
Strategy),
and motor temperature
cutback disabled.
Set: Motor thermistor
input (pin 8) is
at the voltage rail (0 V
or 10 V).
Clear: Bring the motor
thermistor
input voltage within
range.
31
Main Open/Short (RRDCON & ECON
only)
1. Open or short on driver load.
2. Dirty connector pins.
3. Bad crimps or faulty wiring.
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
Set: Main contactor
driver (pin 6) is
either open or shorted.
This fault can
be set only when Main
Enable = On.
Clear: Correct open or
short, and
cycle driver
32
EMBrake Open/Short
(DCON Only)
1. Open or short on driver load.
2. Dirty connector pins.
3. Bad crimps or faulty wiring.
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
Will drag tire with the
bad
brake.
Set: Electromagnetic
brake driver (pin 5) is
either open or shorted.
Thisfault can be set
only when EM Brake
Type >0.
Clear: Correct open or
short, and cycle driver.
33
Coil3 Driver Open/Short
1. Open or short on driver load.
2. Dirty connector pins.
3. Bad crimps or faulty wiring.
ShutdownDriver3.
Set: Driver 3 (pin 4) is
either open or shorted.
Clear: Correct open or
short, and cycle driver.
34
Coil4 Driver Open/Short
1. Open or short on driver load.
2. Dirty connector pins.
3. Bad crimps or faulty wiring.
ShutdownPD.
Set: Proportional driver
(pin 2) is either open
or shorted.
Clear: Correct open or
short, and cycle driver.
35
PD Open/Short
1. Open or short on driver load.
2. Dirty connector pins.
3. Bad crimps or faulty wiring.
ShutdownPD.
Set: Proportional driver
(pin 2) is either open
or shorted.
Clear: Correct open or
short, and cycle driver.
Control System Fault Codes
Summary of Contents for Genie Z-45 DC
Page 121: ...July 2020 Service and Repair Manual 111 Wiring Diagram Options ...
Page 124: ...July 2020 Service and Repair Manual 114 Wiring Diagram Options ...
Page 125: ...July 2020 Service and Repair Manual 115 Schematics Options DC and FE Models ...
Page 127: ...July 2020 Service and Repair Manual 117 Power Cable Wiring Diagram ...
Page 129: ...July 2020 Service and Repair Manual 119 Hydraulic Schematic ...
Page 131: ...July 2020 Service and Repair Manual 121 Electrical Schematic DC FE Models ...
Page 134: ...July 2020 Service and Repair Manual 124 Electrical Schematic DC FE Models ...
Page 136: ...July 2020 Service and Repair Manual 126 Electrical Schematic DC FE Models ...