Operator's Manual
First Edition • Second Printing
Inspections
32
Z-60/37DC • Z-60/37FE
Part No. 1270491
At the Ground Controls
1
Select a test area that is firm, level and free of
obstruction.
2
Turn the key switch to ground control.
3
Pull out the red Emergency Stop button to the
on position.
Result: The beacon (if equipped) should flash.
4
FE models: Start the engine. See Operating
Instructions section.
Test Emergency Stop
5
Push in the red Emergency Stop button to the
off position.
Result FE models: The engine will shut off
after 2 to 3 seconds.
6
Press and hold the function enable button and
activate each boom and platform function
toggle switch.
Result: No functions should operate.
7
Pull out the red Emergency Stop button to the
on position.
Test Machine Functions
8
Do not push and hold the function enable
button. Attempt to activate each boom and
platform function toggle switch.
Result: No boom and platform functions should
operate.
9
Press and hold the function enable button and
activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent
alarm should sound while the boom is
lowering.
Test Emergency Controls
FE Models:
10
Turn the key switch to ground control.
11
Pull out the red Emergency Stop button to the
on position.
12
Select hybrid mode.
13
Simultaneously hold the
emergency power switch on and
activate each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
DC Models:
14
Turn the key switch to ground control.
15
Pull out the red Emergency Stop button to the
on position.
16
Simultaneously hold the
emergency power switch on and
activate each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.