Operator's Manual
First Edition • Second Printing
Operating Instructions
52
Z-60/37DC • Z-60/37FE
Part No. 1270491
Battery and Charger Instructions
Observe and Obey:
Do not use an external charger or booster
battery.
Charge the battery in a well-ventilated area.
Use proper AC input voltage for charging as
indicated on the charger.
Use only a Genie authorized battery and
charger.
To Charge Battery
FE Models: Use the engine or an external power
source to recharge the batteries.
DC Models: Use an external power source to
recharge the batteries.
Be sure the batteries are connected before
charging the batteries.
If machine is equipped with flooded lead acid
batteries, check the battery acid level when the
charging cycle is complete. Replenish with distilled
water to the bottom of the fill tube. Do not overfill.
If the batteries are not charged weekly the
following message will appear on the platform
control LCD screen, FULL PLUG-IN CHARGE
ADVISED WEEKLY FOR BEST BATTERY LIFE.
FE Models: Charging Batteries with Engine
Running the engine will automatically charge the
batteries.
The engine will automatically shut off when the
battery charge cycle reaches 85%.
After the charge cycle reaches 85% the platform
control panel LCD screen will display the following
message, HYBRID CHARGE COMPLETE. PLUG
IN FOR 100% CHARGE.
Charging Batteries with External Power
1
Connect the battery charger to a grounded AC
circuit.
The charger will automatically shut off when the
charging cycle is complete.
If machine is equipped with flooded lead acid
batteries, check the battery acid level when the
charging cycle is complete. Replenish with distilled
water to the bottom of the fill tube. Do not overfill.