Service and Repair Manual
December 2018
Platform Controls
18
Z®-60/37 DC • Z®-60
/37 FE
Part No. 1271125GT
8
Momentarily activate the drive enable toggle
switch in the right direction until CALIBRATE
TILT SENSOR is shown on the display.
9
Momentarily activate steer in the right direction
until VALVE MAXIMUM CURRENT is shown
on the display.
10 Momentarily activate the drive enable switch to
enter the sub menu VALVE MAXIMUM
CURRENT.
High Flow Functions:
The function speeds are fixed by the flow rate
supplied by the hydraulic pump. Excess flow is
rarely produced resulting in little or no oil going over
relief.
11 Momentarily activate and release the high flow
boom function in one direction.
Result: The display shows the name, direction
and current value in milliamps for the function
being moved. Example: “PRI_UP_MAX 590.”
12 Momentarily activate steer right five times to
increase the mA value.
13 Activate the boom function again by pressing
the foot switch and moving the function switch
(or joystick to full speed) in the same direction.
Momentarily active steer left once every three
seconds to decrease the maximum mA value
where pressure rises to about 3000 PSI /
207 bar and an audible alarm sounds.
Note: The turntable function will only increase 300
PSI and no audible alarm. When the 300 PSI
occurs, proceed to the next step.
14 Release the foot switch and momentarily
activate steer in the right direction one time to
increase the value by 10 milliamps. Repeat
releasing the foot switch and momentarily
activating steer right until the function moves
with no valve throttling and no audible alarm
for the primary up/down, secondary up/down
and primary boom extend and retract.
15 Momentarily activate steer in the right direction
three times to increase the value by
30 milliamps for the turntable function setting.
16 Momentarily activate the drive enable switch to
the right to save the value.
Result: The alarm will sound indicating the
setting has been saved. Continue to the next
desired high flow function adjustment.
To exit programming mode:
17 Move and hold the drive enable toggle in the
left position until the display returns to
SYSTEM READY mode.
Summary of Contents for Genie Z-60 DC
Page 54: ...Service and Repair Manual December 2018 Manifolds 44 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 56: ...Service and Repair Manual December 2018 Manifolds 46 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 107: ...December 2018 Service and Repair Manual 97 Wiring Diagram Options ...
Page 110: ...Service and Repair Manual December 2018 100 Schematics Options 4WD DC and FE Models ...
Page 111: ...December 2018 Service and Repair Manual 101 Power Cable Wiring Diagram ...
Page 113: ...December 2018 Service and Repair Manual 103 Hydraulic Schematic DC and FE Models ...
Page 115: ...December 2018 Service and Repair Manual 105 Electrical Schematic DC FE Models ...
Page 118: ...Service and Repair Manual December 2018 108 Electrical Schematic DC FE Models ...
Page 120: ...Service and Repair Manual December 2018 110 Electrical Schematic DC FE Models ...
Page 125: ......