Service and Repair Manual
December 2018
Platform Controls
20
Z®-60/37 DC • Z®-60
/37 FE
Part No. 1271125GT
How t o Adj ust t he Joystic k Ramp R at e Setting
How to Adjust the Ramp Rate
Setting
The ramp rate setting is an adjustment that controls
the way boom function starts and stops. There are
two types of ramp rates to adjust on separate
menus:
Ramp Up Time:
The amount of time it takes to
accelerate to speed.
Ramp Down Time:
The amount of time it takes to
decelerate to a stop.
Note: Perform this procedure with the boom in the
stowed position. Refer to Navigation Menus,
Settings Menu
.
1
Turn the key switch to platform control. Do not
start the engine (if equipped).
2
Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
3
Do not press down the foot switch.
4
Move and hold the drive enable toggle switch
in the right direction while holding steer in the
right direction.
5
When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer joystick.
Result: The display will show FAULTS.
6
Momentarily activate steer in the right direction
until SETTINGS is shown on the display.
7
Momentarily activate the drive enable toggle
switch in the right direction until VALVE AND
SENSOR SETTINGS is shown on the display.
8
Momentarily activate the drive enable toggle
switch in the right direction until CALIBRATE
TILT SENSOR is shown on the display.
9
Momentarily activate steer in the right direction
to choose either RAMP UP TIME or RAMP
DOWN TIME sub menus.
10 Momentarily activate the drive enable toggle
switch in the right direction to enter the desired
ramp time calibration sub menu.
11 Momentarily activate the boom function to be
adjusted.
Result: The display shows the name of the
function, direction, and time value in
milliseconds. Example "PRI_UP_VALVE
2500" (2500 milliseconds / 2.5 seconds of
ramp time).
Note: At this step, the function can be tested and
ramp times can be measured. Release the foot
switch prior to making a parameter adjustment.
12 Momentarily active steer to change the ramp
up or ramp down value. Each activation will
change the value by 50 milliseconds. Refer to
the Ramp Rate chart for factory settings.
Summary of Contents for Genie Z-60 DC
Page 54: ...Service and Repair Manual December 2018 Manifolds 44 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 56: ...Service and Repair Manual December 2018 Manifolds 46 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 107: ...December 2018 Service and Repair Manual 97 Wiring Diagram Options ...
Page 110: ...Service and Repair Manual December 2018 100 Schematics Options 4WD DC and FE Models ...
Page 111: ...December 2018 Service and Repair Manual 101 Power Cable Wiring Diagram ...
Page 113: ...December 2018 Service and Repair Manual 103 Hydraulic Schematic DC and FE Models ...
Page 115: ...December 2018 Service and Repair Manual 105 Electrical Schematic DC FE Models ...
Page 118: ...Service and Repair Manual December 2018 108 Electrical Schematic DC FE Models ...
Page 120: ...Service and Repair Manual December 2018 110 Electrical Schematic DC FE Models ...
Page 125: ......