Service and Repair Manual
December 2018
Platform Components
24
Z®-60/37 DC • Z®-60
/37 FE
Part No. 1271125GT
2-2
Platform Rotator
How to Remove the Platform
Rotator
Component damage hazard. Mark
the platform mounting weldment
and the rotator flange before
removing the platform mounting
weldment. The platform mounting
weldment must be replaced in the
exact same position on the rotator
flange as it was before removal. If
a new rotator is installed or the
rotator is disassembled, proper
alignment can be achieved by
rotating the rotator all the way to
the left and then installing the
platform mounting weldment all the
way in the left position.
Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or hose
end must be replaced. All connections must be
torqued to specification during installation. Refer to
Specifications,
Hydraulic Hose and Fitting Torque
Specifications.
1
Remove the platform and platform support.
2
Tag, disconnect and plug the hydraulic hoses
from the platform rotator manifold. Cap the
fittings on the rotator.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to squirt
or spray.
3
Support the platform rotator with an
appropriate lifting device. Do not apply any
lifting pressure.
Crushing hazard. The platform
rotator may become unbalanced
and fall if not properly supported.
How to Bleed the Platform Rotator
Note: This procedure will require two people. Do not
start the engine. Use auxiliary power for this
procedure.
1
Move the function enable toggle switch to
either side and activate the platform rotate
toggle switch to the right then the left through
two platform rotation cycles, then hold the
switch to the right position until the platform is
fully rotated to the right.
2
Place a suitable container underneath the
platform rotator.
3
Open the top bleed screw on the rotator, but do
not remove it.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
4
Move the function enable toggle switch to
either side and hold the platform rotate toggle
switch to the left position until the platform is
fully rotated to the left. Continue holding the
toggle switch until air stops coming out of the
bleed screw. Close the bleed screw.
Crushing hazard. Keep clear of
the platform during rotation.
Summary of Contents for Genie Z-60 DC
Page 54: ...Service and Repair Manual December 2018 Manifolds 44 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 56: ...Service and Repair Manual December 2018 Manifolds 46 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 107: ...December 2018 Service and Repair Manual 97 Wiring Diagram Options ...
Page 110: ...Service and Repair Manual December 2018 100 Schematics Options 4WD DC and FE Models ...
Page 111: ...December 2018 Service and Repair Manual 101 Power Cable Wiring Diagram ...
Page 113: ...December 2018 Service and Repair Manual 103 Hydraulic Schematic DC and FE Models ...
Page 115: ...December 2018 Service and Repair Manual 105 Electrical Schematic DC FE Models ...
Page 118: ...Service and Repair Manual December 2018 108 Electrical Schematic DC FE Models ...
Page 120: ...Service and Repair Manual December 2018 110 Electrical Schematic DC FE Models ...
Page 125: ......