Service and Repair Manual
December 2018
Platform Components
26
Z®-60/37 DC • Z®-60
/37 FE
Part No. 1271125GT
5
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to step
6.
Result: The system will flash the red “Platform
Overloaded” LEDs and turn on an audible
alarm at both the platform and ground control
stations. Slowly tighten the load spring
adjustment nut in a clockwise direction in 10°
increments until the overload indicator light
turns off, and the alarm does not sound.
Repeat step 5.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
6
Turn the key switch to ground controls, pull out
the red Emergency Stop Button.
7
Add an additional weight to the platform that is
equal to, but does not exceed 15% of the
maximum rated load.
Result: The overload indicator light is flashing
at both the ground and platform controls, the
alarm is sounding. Proceed to step 8.
Result: The overload indicator lights are off at
the platform and ground controls, the alarm
does not sound. Slowly loosen the load spring
adjustment nut in a counterclockwise direction
in 10° increments until the overload indicator
light flashes at both the platform and ground
controls, the alarm sounds and the engine
shuts down. Remove the additional weight.
Repeat the procedure starting with step 5.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
8
Using auxiliary power, test all machine
functions from the ground controls.
Result: All ground control functions should
operate.
9
Using a suitable lifting device, remove the
additional weight from the platform.
Result: The platform overload indicator light
should be off at both the ground and platform
controls and the alarm should not sound.
Note: There may be a 2 second delay before the
overload indicator lights and alarm turn off.
10 Test all machine functions using the function
enable switch at the ground controls.
Result: All ground control functions should
operate.
Summary of Contents for Genie Z-60 DC
Page 54: ...Service and Repair Manual December 2018 Manifolds 44 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 56: ...Service and Repair Manual December 2018 Manifolds 46 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 107: ...December 2018 Service and Repair Manual 97 Wiring Diagram Options ...
Page 110: ...Service and Repair Manual December 2018 100 Schematics Options 4WD DC and FE Models ...
Page 111: ...December 2018 Service and Repair Manual 101 Power Cable Wiring Diagram ...
Page 113: ...December 2018 Service and Repair Manual 103 Hydraulic Schematic DC and FE Models ...
Page 115: ...December 2018 Service and Repair Manual 105 Electrical Schematic DC FE Models ...
Page 118: ...Service and Repair Manual December 2018 108 Electrical Schematic DC FE Models ...
Page 120: ...Service and Repair Manual December 2018 110 Electrical Schematic DC FE Models ...
Page 125: ......