Second Edition • First Printing
Operator's Manual
Inspections
Part No. 1304187GT
Z
®
-62/40 • Z
®
-62/40 TRAX
™
41
At the Platform Controls
Test Emergency Stop
15
Turn the key switch to platform control and
restart the engine.
16
Push in the platform red Emergency Stop
button to the off position.
Result: The engine will shut off after 2 to
3 seconds.
17
Pull out the red Emergency Stop button and
restart the engine.
Test the Horn
18
Press the horn button.
Result: The horn should sound.
Test the Foot Switch
19
Push in the platform red Emergency Stop
button to the off position.
20
Pull out the red Emergency Stop button to the
on position and do not start the engine.
21
Press down the foot switch and attempt to start
the engine by moving the start toggle switch to
either side.
Result: The engine should not start.
22
Do not press down the foot switch and restart
the engine.
Result: The engine should start.
23
Do not press down the foot switch and test
each machine function.
Result: No functions should operate.
Test Machine Functions
24
Press down the foot switch.
25
Activate each machine function control handle
or toggle switch.
Result: All boom and platform functions should
operate through a full cycle.
Test the Steering
26
Press down the foot switch.
27
Press the thumb rocker switch on top of the
drive control handle in the direction indicated
by the blue triangle on the control panel OR
slowly move the control handle in the direction
indicated by the blue triangle.
Result: The steer wheels, or steer tracks
should turn in the direction that the blue
triangles point on the drive chassis.
28
Press the thumb rocker switch in the direction
indicated by the yellow triangle on the control
panel OR slowly move the control handle in the
direction indicated by the yellow triangle.
Result: The steer wheels, or steer tracks
should turn in the direction that the yellow
triangles point on the drive chassis.
Summary of Contents for Genie Z-62/40