Inspections
Part No. 1258936
ZX-135/70 35
At the Platform Controls
Test Emergency Stop
34
Turn the key switch to platform control.
35
Push in the platform red Emergency Stop
button to the off position.
Result: The engine should shut off and no
functions should operate.
36
Pull out the red Emergency Stop button and
restart the engine.
Test the Horn
37
Press the horn button.
Result: The horn should sound.
Test the Tilt Sensor Alarm
38
Move a toggle switch, such as the engine idle
select switch.
Result: The alarm should sound at the platform
controls.
Test the Foot Switch
39
Push in the platform red Emergency Stop
button to the off position.
40
Pull out the red Emergency Stop button to the
on position and do not start the engine.
41
Press down the foot switch and attempt to start
the engine by moving the start toggle switch to
either side.
Result: The engine should not start.
42
Do not press down the foot switch and restart
the engine.
Result: The engine should start.
43
Do not press down the foot switch and test
each machine function.
Result: No functions should operate.
Test Machine Functions
44
Press down the foot switch.
45
Activate each function control handle, toggle
switch or thumb rocker switch.
Result: All functions should operate through a
full cycle.