Second Edition • Third Printing
Operator's Manual
Operating
Instructions
Part No. 1258936
ZX-135/70 53
LCD Screen (if equipped)
The LCD screen displays hour meter, voltage, oil
pressure and coolant temperature. The screen
also displays fault codes and other service
information.
Perkins Engine
Machines equipped with Perkins 854F-34T Diesel
engines have a regeneration mode that should run
automatically when needed.
LCD will display REGEN FORCED and WARNING
HIGH EXHAUST SYSTEM TEMP when the
regeneration mode is running. No service required.
Machine Not Level Indicator Light
If the tilt alarm sounds when the
platform is raised, the Machine
Not Level indicator light will come
on and the drive function in one or
both directions will not operate.
Identify the condition of the boom
on the slope as shown below.
Follow the steps to lower the
boom before moving to a firm,
level surface. Do not rotate the
boom while lowering.
If the tilt alarm sounds with
the platform uphill:
1
Lower the primary
boom.
2
Lower the secondary
boom.
3
Retract the primary
boom.
If the tilt alarm sounds with
the platform downhill:
1
Retract the primary
boom.
2
Lower the secondary
boom.
3
Lower the primary
boom.