Bucket
Display reads:
Fault results in:
Possible causes:
Solution:
Invalid propel mode
selection
Bucket control disabled
Valid propel mode not selected
Select valid propel mode
Loader Speed selection
above upper limit
Automatically sets speed to 100%
Loader speed set above 100%
Select valid speed
Loader Speed selection
below lower limit
Automatically sets speed to 50%
Loader speed set below 50%
Select valid speed
Loss communications
between Main Controller
and Right Joystick
Bucket control disabled
Faulty connections or wires between main
controller and right joystick
Restore connections, then cycle power by tur
the key off then back on
Keypad CAN Fault -
Loss of Keypad
CAN communications
Auto level disabled (if equipped)
Faulty connections or wires between main
controller and keypad
Restore connections, then cycle power by tur
the key off then back on
Loss communications
between Main Controller
and Output Module
Bucket control disabled
Faulth connections or wires between main
controller and output module
Restore connections, then cycle power by tur
the key off then back on
Right Joystick Y-Axis
outside of specified
limits
Bucket control disabled
Joystick Faulty
Replace joystick, then cycle power.
Invalid Keypad installed
Auto level disabled (if equipped)
CE keypad installed in US machine or vice versa. Install correct keypad for your machine.
Lap Bar Switch
Fault (both inputs off)
Bucket control disabled
Switch faulty, wiring connection faulty, switch out
of adjustment.
Restore connections, adjust or replace switch
then cycle power by turning the key off then b
on
Lap Bar Switch
Fault (both inputs on)
Bucket control disabled
Switch faulty, wiring connection faulty, switch out
of adjustment.
Restore connections, adjust or replace switch
then cycle power by turning the key off then b
on
Bucket Curl solenoid
short circuit
Bucket curl/dump disabled
Work enable solenoid de-energized
Solenoid shorted to battery (faulty wires,
connections)
Restore connections, then cycle power by tur
the key off then back on
Bucket Curl solenoid
short circuit
Bucket curl/dump disabled
Work enable solenoid de-energized
Solenoid shorted to ground (faulty wires,
connections)
Restore connections, then cycle power by tur
the key off then back on
Bucket Curl solenoid
open circuit
Bucket curl disabled
Solenoid open circuit (faulty wires, connections)
Restore connections, then cycle power by tur
the key off then back on
Bucket Dump solenoid
short circuit
Bucket curl/dump disabled
Work enable solenoid de-energized
Solenoid shorted to battery (faulty wires,
connections)
Restore connections, then cycle power by tur
the key off then back on
Bucket Dump solenoid
short circuit
Bucket curl/dump disabled
Work enable solenoid de-energized
Solenoid shorted to ground (faulty wires,
connections)
Restore connections, then cycle power by tur
the key off then back on
Bucket Dump solenoid
open circuit
Bucket dump disabled
Solenoid open circuit (faulty wires, connections)
Restore connections, then cycle power by tur
the key off then back on
Work Enable solenoid
fault
Bucket control disabled
Solenoid shorted to battery (faulty wires,
connections)
Restore connections, then cycle power by tur
the key off then back on
Work Enable solenoid
fault
Bucket control disabled
Solenoid shorted to ground (faulty wires,
connections)
Restore connections, then cycle power by tur
the key off then back on
Work Enable solenoid
fault
Bucket control disabled
Solenoid open circuit (faulty wires, connections)
Restore connections, then cycle power by tur
the key off then back on
18-7
Compact Track Loader
18. Troubleshooting
Bucket
Summary of Contents for PT100G Forestry
Page 1: ...PT 100G PT 100G Forestry Part Number 2076 286 Printed 8 10 Service Manual Compact Track Loader...
Page 2: ......
Page 6: ......
Page 12: ......
Page 14: ......
Page 22: ......
Page 40: ......
Page 52: ......
Page 62: ......
Page 66: ......
Page 80: ......
Page 98: ......
Page 102: ......
Page 116: ......
Page 136: ......
Page 138: ......
Page 140: ......
Page 141: ......