8.
Separate the return fuel line connector plug
located behind the oil dipstick on the ride side of
the engine (fig. 12-22).
9.
Disconnect the battery cable, ground cables, and
other wires from the starter on the left side of
the engine compartment (fig. 12-23).
10.
Disconnect the wire harness from the alternator
and the glow plug connector on the left side of the
engine compartment (fig. 12-24).
11.
Disconnect the ECU wire harness connector from
the ECU (computer), located behind the oil dip
stick on the right side of the engine compartment
and then loosen the center bolt on the connector
to allow it to be unplugged (fig. 12-25).
12.
Remove the lower three springs from exhaust pipe
and then remove the three bolts that secure the
pipe to the engine. Remove the pipe (fig. 12-26).
13.
Loosen the hose clamp on the air intake located
on the left side of the engine and right tower
(fig. 12-27).
12-6
Compact Track Loader
12. Engine
12-23
12-22
12-24
12-25
12-26
12-27
Fuel line
return
ground terminal
Glow plug
connector
ECU wire
harness
Bolt
Springs
solenoid terminals
Disconnect