1.
Rest the lift arms on an Terex approved jack stand
to provide clearance for lift cylinder removal. (fig.
14-1)
2.
Disconnect the inlet and outlet hoses from the
cylinder. (fig. 14-2)
3.
Label the hoses according to right and left orienta-
tion to simplify reassembly, then cap and plug the
hoses and fittings to prevent fluid loss and or sys-
tem contamination. (fig. 14-3)
4.
Remove the bolts securing the front and rear lift
arm cylinder pivot pins to the lift arm and lift arm
tower. (fig. 14-4)
5.
Remove the grease fitting from the pivot pins to
allow the installation of the pin removal tool. (fig.
14-5)
6.
Thread the removal tool into each pin, then use
the slide hammer to extract them. (fig. 14-6)