Compact track Loader
14. Hydraulic Pressure Check & Adjustment
14-3
Figure 14-5
4.
To adjust the auxiliary pressure, loosen the jam
nut and turn the adjustment screw in with an al-
len wrench to increase pressure and turn screw
out to decrease pressure. Tighten jam nut when
after adjustment has been made.
DO NOT ex-
ceed 3,000 psi (20,680 kPa)
.
DA Control (set procedure)
The service tools required for the DA Control set
procedure are listed in table 14-3. Use manufacturer
recommended tools whenever possible.
Table 14-3
Required Tools
Allen Wrench
Combination Wrench
Figure 14-6
1.
To set the DA control, loosen lock nut, then turn
the set screw in until it lightly bottoms out. Back
the set screw out 5.5 turns. Then, while holding
the set screw in place, tighten the lock nut to
secure.
Jam Nut
Adjustment
Screw