Document 57.0300.0200 - 4
th
Edition 07/2000
- Forlì
Page
38
Robot
D-3
FAULTS AND TROUBLESHOOTING
The robot with platform is an equipment coupled to an
handler. A defective handler may affect its proper func-
tioning. For this reason, it is recommended to read the
handler manual for all faults which are not listed below.
D-3.1 Faults - Causes - Solutions
• Plug is not connected
• Robot locking sensor wrongly
positioned
• Controls not switched from handler
to platform
• Stabilisers are up
• Key-switch
A
set to “Cab controls”
• Platform overload
THE WORK PLATFORM
CONTROLS DO NOT FUNCTION
WARNING LAMP “B”
(fig. C10)
DOES NOT SWITCH ON
ALARM SIGNALLED BY THE
OVERLOAD WARNING SYSTEM
• Ensure the power plug on the boom
has been properly plugged in (see
C-1)
•
Adjust the sensor distance (see
section
Maintenance - Adjusting
the sensor distance
in the opera-
tor’s handbook of the handler)
• Try to switch again the controls from
handler to platform (see C-6.1)
• Lower the stabilisers
• Set the switch to “Platform controls”
• Remove any load in excess from the
platform. For the payload limits, read
chapter C-6.
MAINTENANCE
D
Summary of Contents for Robot 15000
Page 2: ......
Page 4: ......
Page 6: ...Document 57 0300 0200 4th Edition 07 2000 Forl Page 2 Robot Intentionally blank page...
Page 9: ...Document 57 0300 0200 4th Edition 07 2000 Forl Page 5 Robot Section A GENERAL INFORMATION...
Page 21: ...Document 57 0300 0200 4th Edition 07 2000 Forl Page 17 Robot Section B SAFETY...
Page 25: ...Document 57 0300 0200 4th Edition 07 2000 Forl Page 21 Robot Section C OPERATING INSTRUCTIONS...
Page 37: ...Document 57 0300 0200 4th Edition 07 2000 Forl Page 33 Robot Section D MAINTENANCE...