Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
4
43
TELELIFT 3713 Elite - 4017 - 4514
SCHEDULED MAINTENANCE PROCEDURES
4.6
TABLE D PROCEDURES
D-1 VISUALLY CHECK THE SMOKE QUANTITY
EVACUATED FROM THE ENGINE
EXHAUST
To check the quantity of smoke evacuated from the
engine exhaust, proceed as follows:
-
Start the engine of the machine.
-
Wait for a few minutes so the engine can warm up
correctly.
-
Visually check that the amount of smoke coming out
of the exhaust is normal; repeat the check while
accelerating the engine.
Do this check outdoors or use an adequate smoke
extraction system.
In case of excess smoke, strictly obey the
instructions provided in the relevant Use and
maintenance manual enclosed with the technical
literature of the machine.
D-2 CHECK THE TIGHTENING OF THE ENGINE
FIXING SCREWS
Every 6 months, check that the screws fixing the engine
to the machine chassis are tight.
For this operation, use a torque wrench and tighten the
screws to a torque of
146 Nm
.
Summary of Contents for TELELIFT 3713 Elite
Page 4: ...Courtesy of Crane Market...