Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
5
13
TELELIFT 3713 Elite - 4017 - 4514
TROUBLESHOOTING
Trouble
Cause
Solution
The left outrigger does not move up
The right outrigger does not move
down
Tecnord control unit damaged
Solenoid
Y13-E
damaged
Low boom sensor (
B38
) damaged
Outrigger switch
S1
damaged
Tecnord control unit damaged
Solenoid
Y12-D
damaged
Low boom sensor (
B38
) damaged
Outrigger switch
S2
damaged
Tecnord control unit damaged
Solenoid
Y11-C
damaged
Check you have 12V on connector
J1
on pin
5B
and on connector
J2
to pin
2A
when the movement is done; if
necessary, change the control unit.
During movement, check you have 12V
between the two contacts of the coil;
or change the solenoid.
Check the sensor ; check you have 12V
on connector
J1
on pin
3A
; change the
sensor, if necessary.
Check you have 12V on contact
3
of
the switch, and 12V on contact
7
of the
switch when the movement is done.
Change the switch, if necessary.
Check you have 12V on connector
J1
on pin
4A
and on connector
J2
to pin
1A
when the movement is done; if
necessary, change the control unit.
During movement, check you have 12V
between the two contacts of the coil;
or change the solenoid.
Check the sensor ; check you have 12V
on connector
J1
on pin
3A
; change the
sensor, if necessary.
Check you have 12V on contact
3
of
the switch, and 12V on contact
1
of the
switch when the movement is
done.Change the switch, if necessary.
Check you have 12V on connector
J1
on pin
6C
and on connector
J2
to pin
4A
when the movement is done; if
necessary, change the control unit.
During movement, check you have 12V
between the two contacts of the coil;
or change the solenoid.