Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
6
31
TELELIFT 3713 Elite - 4017 - 4514
SCHEMES
Connector J2 - output signals
1A
= left outrigger up
2A
= left outrigger down
3A
= right outrigger up
4A
= right outrigger down
5A
= sway left
6A
= sway right
7A
= boom out/in signal
8A
= ground
1B
= attachment locking/unlocking signal
2B
= joystick button common line (+12 V)
3B
= N.C.
4B
= N.C.
5B
= fork rotation signal
6B
= N.C.
7B
= N.C.
8B
= +12 V battery
1C
= attachment unlocking signal
2C
= +12 V for alarm indicator on platform
3C
= +12 V with operated joystick
4C
= N.C.
5C
= +12 V for sound alarm on platform
6C
= N.C.
7C
= N.C.
8C
= boom lift/lower signal
Summarising table of the voltage values of the boom movements
Up
Down
Out
In
Fork
Fork
rotation - Open rotation - Close
Joystick in rest
position (2.5 V)
•
•
•
•
•
•
0.7 V
•
•
•
4.25 V
•
•
•
Summary of Contents for TELELIFT 3713 Elite