Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
6
32
TELELIFT 3713 Elite - 4017 - 4514
SCHEMES
6.8
TECNORD BUTTON PANEL CONNECTIONS
EL. PUMP
ON
D.M.
STOP
START
E.PUMP COMM.
11
P2
15
12
DEAD MAN
+ BUZZER
10
09
P1
L1
BUZZER
BZ1
SIGN. F2
SIGN. F1
+5VDC
GND
KEY ON
SW1/1
08
07
06
05
04
+ LIM. IND.
+12VDC
03
02
01
6
5
4
6
5
4
JLP2
JLP1
LIMIT.
L2
PE/2
PE/1
16
P3
START
18
17
OVERLOAD
EXCEL POWER SUPPLY
EXCEL GND
SW1/2
CONNECTIONS
:
1) +POWER (+12VDC)
2) LIMITER INDICATOR
3) NOT USED
4) NOT USED
5) GND (0VDC)
6) + POTENT. (+5VDC)
7) FUNCTION 1 SIGNAL
8) FUNCTION 2 SIGNAL
9) BUZZER
10) DEAD MAN
11) EL. PUMP COMMAND
12) STOP COMMAND
13) START COMMAND
14) OVERLOAD (SIGNAL FROM EXCEL)
15) EXCEL POWER SUPPLY
16) EXCEL GND
STOP
G
ON
OFF
JLP2 = BOOM OUT/IN
L1 = POWER WARNING LIGHT
JLP1 = BOOM UP/DOWN
PE = EMERGENCY STOP
Mushroom-head emerg.button
Green LED indicator 12VDC
JLP 80%
P.N. Function
Description
L2 = LIM. WARNING LIGHT
Red LED indicator 12VDC
P1 = U.P. BUTTON
Button, instable, 1NO
P2 = EL. PUMP BUTTON
Button, instable, 1NO
SW1 = ENABLING KEY
Key-switch, stable, 2NO
BZ1 = BUZZER (INTERNAL)
Buzzer 90db
Button, instable, 1NO
P3 = START BUTTON
Summary of Contents for TELELIFT 3713 Elite