Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
7
10
TELELIFT 3713 Elite - 4017 - 4514
REPAIR PROCEDURES
7.2.3
Strain load cell tightening (Telelift 4017-
4514)
3
2
1
In order to get the best results and avoid damaging the
strain gage, follow these precautionary measures:
1 - PREPARATION:
-
Thoroughly clean the whole tightening system,
especially the ground and unpainted area.
2 - ASSEMBLY:
-
Apply the strain gage with its resinated side facing
the axle and holding the cable(s) toward the machine.
-
Tighten the two screws with a torque wrench at 70
N/m.
-
Mark the position of the screws with paint in order to
make possible loosening visible to the eye.
Ground and unpainted area
for strain cage support
Wheel side
Resin side view
Axial plane
Machine side
(strain cage cable output)
1
= Strain cage
2
= Washer ø 10
3
= Fastening screw M10x40.