Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
2
38
TELELIFT 3713 Elite - 4017 - 4514
TECHNICAL SPECIFICATIONS
Alarm code 2
Alarm code 3
The analog command signals of the control modules of the boom, telescopes and inclination movements are
signals between 0.9V (-84.2%) and 4.1V(+84.2%) with rest position at 2.5V (0%).
REMARK
-
PERC_cmd = (Vcontrol – 2.5)/1.9
-
Corsa MASSIMA FW e BW mean the maximum stroke in one direction and the maximum stroke in the opposite
drection
-
With the calibration program, you can change the piloting percentages of MAX FW, min FW, MAX BW and min
BW for the three proportional manoeuvres.
Corsa distributore
PERC_cmd
(%)
87
MAX FW
MIN FW
Zero
MIN BW
Corsa massima BW
MAX BW
-87
Corsa massima FW
Summary of Contents for TELELIFT 3713 Elite
Page 4: ...Courtesy of Crane Market...