Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
2
51
TELELIFT 3713 Elite - 4017 - 4514
TECHNICAL SPECIFICATIONS
N°
Winscope Name
Description
00
C1cellaVuoto
Value saved in analog channel 1 - calibration with unloaded machine (best setting
around 700).
01
C1cellaCarico
Value saved in analog channel 1 - calibration with loaded machine (best setting
around 300).
02
C1cellaMin
Min admissible value for analog channel 1 reading (if actual value is below: alarm
2) (value set at 10 roughly).
03
C1cellaMax
Max admissible value for analog channel 1 reading (if actual value is above: alarm
2) (value set at 1010).
04
C2cellaVuoto
Value save in analog channel 2 - calibration with unloaded machine (best setting
around 300).
05
C2cellaCarico
Value save in analog channel 2 - calibration with loaded machine (best setting
around 700).
06
C2cellaMin
Min admissible value for analog channel 1 reading (if actual value is below: alarm
3) (value set at 10 roughly).
07
C2cellaMax
Max admissible value for analog channel 1 reading (if actual value is above: alarm
3) (value set at 1010).
08
Filter
Number of filter samples, with mobile mean. Load cell reading . Max 5.
09
paCellaUnica
Sets to 1 automatically (during the machine selection) when the DLE is used in
single channel mode.
10
Celle_MaxDelta
Max admissible delta between readings of analog channels 1 and 2, expressed
as a %. Default value 10 (current 20).
11
SpanForche
Limiter intervention percentage in case of work with stabilised machine and forks.
Default: 100 (as per calibration).
12
SpanNavicella
Limiter intervention percentage in case of work with stabilised machine and
platform (changed by the relevant procedure during calibration). When the platform
is selected, the limiter uses this % (default 110% - load increase of 10%) instead
of the SpanForche datum (current value 125).
13
DeltaSpanGomme
Limiter intervention percentage in case of work with non-stabilised machine
(changed by the relevant procedure during calibration). % value that adds to the
calibration with forks and outriggers (SpanForche).
14
OffSet0
Command given to the digital potentiometer for cell 1 (value from 0 to 255) to set
the reading scale during calibration with unloaded machine to a certain pre-set
value (about900 bit ADC - C1cellaVuoto) (about 700).
15
OffSet1
Command given to the digital potentiometer for cell 2 (value from 0 to 255) to set
the reading scale during calibration with unloaded machine to a certain pre-set
value (about 200 bit ADC - C2cellaVuoto) (about 300).
16
paIsteresiSblocco
Load % for the reset of the movements once the block condition has been rectified
(default 5% = 95%).
17
paRitardoSblocco
Value expressed in tenths of second corresponding to the time that must elapse
between the block condition and the movement reset (default 10 = 1 second).
20
C1NavicellaVuoto
Parameters 20, 21, 22 and 23 are usually equivalent to parameters 0, 1, 4 and 5,
and they are used when the platform must be calibrated regardless of the
calibration done with the forks.
Value saved in analog channel 1 during calibration with empty machine
21
C1NavicellaCarico
Value saved in analog channel 1 during calibration with loaded machine
22
C2NavicellaVuoto
Value saved in analog channel 2 during calibration with empty machine
23
C2NavicellaCarico
Value saved in analog channel 2 during calibration with loaded machine
24
CurMacchina
Machine selected on point "0" of the calibration
28
VersioneSW
Software version
29
WPsum
Parameters CHECKSUM used by the safety functions
LIST OF THE DLE PARAMETERS