background image

34

08/2020 - EN

[cm]

X1

60

X2

60

Y1

80

Y2

10

Z

100

Product images are purely indicative

SCOOP REMOVAL

MINIMUM DISTANCE FROM COMBUSTIBLE MATERIALS

Z

X1

X2

Y1

Y2

Summary of Contents for FANCY 12

Page 1: ...tenance or use of the product Product images are purely indicative AIR PELLET STOVES EN GENERAL INFORMATION WARNINGS INSTALLATION MAINTENANCE This product complies with the 4 star class as per the emission and performance standards of Italian Legislative Decree no 186 7th November 2017 FANCY 12 ECO DESIGN 2022 CONTO TERMICO ...

Page 2: ...stoves are supplied ready for the optional Wi Fi module allowing the automatic management of functions through the Termovana App available on Apple Store and Google Play Or else through Amazon Alexa voice commands and coming soon Google Home Download the Termovana App and automatically manage your stove by remote Dear Customer We d like to thank you for having purchased one of our products and con...

Page 3: ... MANUAL MODE 8 13 MANUAL 8 14 AUTO 9 USER PROGRAMMING 19 9 1 DATE AND TIME SETTINGS 9 2 WEEKLY PROGRAMMER 9 3 PROGRAM NUMBER 9 4 DAY OF THE WEEK 9 5 HOURS 9 6 MINUTES 9 7 REQUIRED TEMPERATURE 9 8 REQUIRED PROGRAM 9 9 PROGRAM TYPE 9 10 ENABLING THE PROGRAM 1 1 EXAMPLE OF PROGRAMMING 1 STOVE PARAMETERS 20 1 1 LOADING PELLETS 1 2 FUME EXTRACTION 1 3 ROOM FAN 2 LANGUAGE SELECTION 3 LAST ERROR LOG 4 DU...

Page 4: ...CTION The product subject of this manual was manufactured and tested according to the safety requirements stated in the reference European directives This manual is intended for stove owners installers users and maintenance personnel of the stove and is an integral part of the product In case of uncertainty about the content and for any clarification contact the manufacturer or the authorised tech...

Page 5: ... Failure to arrange for the annual cleaning of the stove by an authorised technician or qualified personnel shall invalidate the warranty Parts subject to normal wear such as gaskets glass cast iron cladding and grilles painted chrome plated or gilded details handles and electrical cables lamps luminous indicators knobs all parts that can be removed from the fire box Colour variations of painted a...

Page 6: ...ser of the stove must be an adult and responsible person having the knowledge needed for routine maintenance of the stove components Make sure that children do not come close to the stove while it is running with the intent to play 1 11 TECHNICAL ASSISTANCE DELKA provides a dense network of specialist technical assistance centres trained and prepared directly at the company The head office and our...

Page 7: ... must wear safety gloves D must wear safety shoes E must use electrical insulated tools F must ensure that the area affected by the phases of assembly and disassembly is free from obstacles 2 2 WARNING FOR THE MAINTENANCE TECHNICIAN Observe the prescriptions contained in this manual Always use individual safety devices and other means of protection If the floor is made of combustible material it i...

Page 8: ...otection in a non combustible material steel glass that also protects the front part in the event of any fuel spills during cleaning operations 2 3 1 WARNINGS AND RECOMMENDATIONS FOR THE USER Observe the prescriptions contained in this manual Respect the instructions and warnings highlighted by the plates displayed on the stove The plates are safety devices therefore they must always be perfectly ...

Page 9: ... temperature and humidity are acceptable Wet and or cold pellets 5 C reduce the thermal potential of the fuel resulting in the need for more cleaning maintenance of the burn pot unburned material and of the firebox Pay particular attention to the storage and handling of pellet bags Their crushing and the formation of sawdust must be avoided If sawdust is introduced into the stove s tank this could...

Page 10: ...ive equipment are intact and functioning perfectly C must wear safety gloves D must wear safety shoes E must use electrical insulated tools F must ensure that the area affected by the phases of assembly and disassembly is free from obstacles 5 3 STOVE INSTALLATION SITE On page 34 of this manual the minimum clearances are shown expressed in cm which must be respected when positioning the stove with...

Page 11: ... so that it is not accidentally obstructed If it is impossible to create the external air intake in the rear wall of the stove non perimeter wall a hole must be created in an external wall of the room where the stove is positioned If it is not possible to create the external air intake in the room an external hole can be created in an adjacent room provided it communicates permanently with a trans...

Page 12: ...ke a maximum of 3 changes of direction in addition to that resulting from the rear connection of the stove to the chimney using 45 90 bends or T fittings fig 5 7 Always use a T fitting with an inspection cap at each horizontal and vertical variation of the flue gas exhaust pipe On the first T at the exit of the flue gas outlet of the stove it is necessary to connect a pipe at the bottom in order t...

Page 13: ... be intubated with a suitably insulated steel pipe with diameter in line with the route Fig 5 9 Make sure that the connection to the brickwork chimney is properly sealed If the pipes pass through roofs or wooden walls you should use special certified transition kits commercially available 5 6 LEVELLING THE STOVE The stove must be levelled with the help of a spirit level by regulating the adjustabl...

Page 14: ...PTIMISATION OF COMBUSTION Excellent fuel depends on different factors type of installation operating and maintenance conditions type of pellets etc When first switched on the stove combustion can be optimised Generally speaking if at the end of combustion there is a lot of residue in the burn pot you should change the combustion configuration by increasing the value until you find the best solutio...

Page 15: ...t deposits before they block the passage of the fumes In the event of failure or inadequate cleaning the stove may have functional problems such as bad combustion glass blackening blockage of the burn pot with accumulation of ash and pellets risk of flue catching fire 6 1 2 STOVE MAINTENANCE It must be carried out at least once a year or each time the stove indicates that maintenance is required D...

Page 16: ...en the fireplace is off and the power supply disconnected remove the entire electric system separate the accumulators in the electronic cards the demolition of the stove s structure should be carried out by authorised companies ATTENTION Dumping the stove in accessible areas poses a serious risk for people and animals Any liability for damage to people and animals always falls on the owner At the ...

Page 17: ... pellets bad chimney draught etc Therefore the preservation of the paint in the combustion chamber cannot be guaranteed During the first hours of operation greasy processing residues and paints may produce odours and smoke it is recommended to ventilate the room because they can be harmful to people and animals The programming values from 1 to 5 are preset by the company and can be modified by an ...

Page 18: ...e stove reports any detected fault by means of an error code and a comment Before turning the stove on again it is necessary to reset all errors by pressing the STOP key for about 3 seconds and in any case until the error message on the LCD display disappears The last 10 errors are saved in a non volatile memory and can be viewed by entering the ERROR LOG menu 8 10 Heating Mode It is possible to c...

Page 19: ... days from Monday to Friday MF or else for weekends from Saturday to Sunday SS This system allows the setting of a single programme to turn the stove on or off every day from Monday to Friday at the same time 9 5 Hours Stove on or off hour 9 6 Minutes Stove on or off minutes 9 7 Required Temperature In the case of ignition program it is necessary to set the required room temperature between 5 and ...

Page 20: ...and by function directly in the user menu The stove will therefore automatically go to stand by mode if the measured room temperature exceeds the programmed temperature The stove will restart when the measured room temperature drops below the programmed temperature 11 LANGUAGE SELECTION It is possible to select a language for the messages on the display from Italian English French German Spanish D...

Page 21: ...l to 50 of the set RPM value an error is generated due to malfunction of the smoke extraction motor and the stove will switch to cooling mode at maximum speed This problem may also be due to ash deposited in the flue gas pass and due to insufficient routine maintenance 14 8 ERROR 8 NOT ACTIVE 14 9 ERROR 9 NOT ACTIVE 14 10 ERROR 10 NOT ACTIVE 14 11 ERROR 11 NOT ACTIVE 14 12 ERROR 12 POWER FAILURE I...

Page 22: ... will light up During long periods of non use it is recommended to position the switch on the back of the machine to OFF O Do not touch the control panel when the stove is powered on 15 3 IGNITION Before each ignition make sure that the burn pot is completely empty and correctly positioned in its seat To turn on the stove keep the key pressed for a few seconds Avoid manually turning on the stove i...

Page 23: ...ove can be switched on off manually or programmed The stove modulates the power according to the room temperature detected by the probe on board i e the stove attempts to maintain the desired temperature by consuming as little fuel as possible If the user has enabled the Standby function rather than modulate the stove will turn off when the set temperature is reached then re ignite when the ambien...

Page 24: ...door open or pellet door open Close the fire door and pellet door and check that there are no pellet granules along the gasket USER Clogged stove Clean the flue gas chamber USER Auger blocked by a foreign object such as nails Clean auger TECHNICIAN Broken auger gearmotor Replace the gearmotor TECHNICIAN Check that there are no ACTIVE ALARMS on the display Service the stove TECHNICIAN The flame tur...

Page 25: ...n continues to turn even if the stove has cooled Defective flue gas tempera ture probe Replace the flue gas probe TECHNICIAN Faulty electronic circuit board Replace the circuit board TECHNICIAN Ash around the stove Faulty or broken door ga skets Replace the gaskets TECHNICIAN Flue gas ducts not sealed Consult a flue specialist who will immedia tely seal the connectors with silicone for high temper...

Page 26: ...mplify the cleaning operations Cleaning the flue compartment The flue compartment must be cleaned every 2 months or whenever necessary After cleaning the burn pot remove it and clean the compartment that contains it fig 2 Remove the ash drawer and using a special ash vacuum remove any residues in the compartment that contains it CAUTION to clean the exchanger circuit and flue box contact a qualifi...

Page 27: ... once per year Cleaning the tank and auger Each time the pellets are refilled check for the presence of any dust sawdust or other scraps on the bottom of the tank If present remove it with the help of a vacuum cleaner The hand protection grille must never be removed from its housing Clean the bottom of the tank and the visible part of the auger Cleaning the painted metal parts Use a damp cloth to ...

Page 28: ...he side panels Fig 4 Remove the screws and remove the rear smoke casing Fig 5 Remove the screws and remove the fan casing with its motor Fig 6 7 Remove the screws and turn the motor to position 1 or 2 Fig 8 9 Repeat the reverse operation Fig 1 Fig 2 For ducting it is recommended not to use more than 6 metres of pipe and 3x90 elbows otherwise the hot air will lose its effectiveness Use 60 mm diamet...

Page 29: ...ITALIANO ENGLISH 29 08 2020 EN WIRING DIAGRAM 18 3RD TANGENTIAL FAN Fixing screws AMB EXCHANG ...

Page 30: ...eat output 13 O2 Emissionen bei CO Teillast 13 O2 Emissions de CO réf 13 O2 à puissance partielle Emisiones de CO ref 13 O2 a potencia parcial Distanza minima da materiali infiammabili Distance between sides and combustible materials Mindestabstand zu brennbaren Bauteilen mind Distance minimum avec matériaux inflammables Distancia mínima con materiales inflammables Tensione Voltage Spannung Tensio...

Page 31: ...pulsion humos C Ventilatore ambiente Room fan Ventilateur ambiant Raumluftgeblaese Ventilador de conveccion D Dosatore caricamento Feeding system Systeme d alimentation Spender Dosador E Termostato di sicurezza Thermostat Thermostat Raumtemperaturregler Termostato F Pressostato Vacuum switch Pressostat Druckwaechter Presostato G Sonda ambiente Room probe Sonde ambiant Raumsonde Sonda ambiente H So...

Page 32: ...des fumees Abgasrohr Tubo salida humos K Sonda ambiente Probe Sonde ambiant Sonde Sonda ambiental L Cavo di alimentazione Power cord Cable d alimentation Speisekabel Cable de alimentación M Interruttore di accensione Main switch Interrupteur general Steuerung der einschaltzeiten Interruptor N Tubo aria comburente Air intake Tube pour l air comburant Verbrennungsluftrohr Tubo aire comburente O Usci...

Page 33: ...pth x Height 57 x 57 2 x 102 3 cm Minimum safety clearances Front Side Rear 80 60 10 cm Flue gas outlet 80 mm External air intake Ø 10 cm Fuel Wood Pellet Minimum draught for chimney sizing 0 0 Pa Stove suitable for rooms no smaller than 30 m3 Feeding tank capacity 16 kg Weight 113 kg Maximum flow rate of optional tangential fan 150 m3 h Ducted 1 and 2 134 4 m3 h cad Energy rating A Stufa con circ...

Page 34: ...34 08 2020 EN cm X1 60 X2 60 Y1 80 Y2 10 Z 100 Product images are purely indicative SCOOP REMOVAL MINIMUM DISTANCE FROM COMBUSTIBLE MATERIALS Z X1 X2 Y1 Y2 ...

Page 35: ...ITALIANO ENGLISH 35 08 2020 EN DIMENSIONS Dimensions mm 1022 6 565 1 572 116 205 200 208 FANCY 12 ...

Page 36: ...36 08 2020 EN CERTIFICAZIONI CERTIFICATIONS ZERTIFIZIERUNGEN CERTIFICATIONS CERTIFICACIONES CERTIFICAZIONI CERTIFICATIONS ZERTIFIZIERUNGEN CERTIFICATIONS CERTIFICACIONES ...

Page 37: ...ITALIANO ENGLISH 37 08 2020 EN FANCY 12 ...

Page 38: ...38 08 2020 EN FANCY 12 ...

Page 39: ...ITALIANO ENGLISH 39 08 2020 EN FANCY 12 ...

Page 40: ...ee to modify the features of its products without prior notice Die Firma DELKA übernimmt für eventuelle Fehler in diesem Heft keine Verantwortung und behält sich das Recht vor die Eigenschaften ihrer Produkte ohne Vorbescheid zu ändern DELKA décline toute responsabilité en cas d erreurs dans la présente documentation et conserve la faculté de modifier sans préavis les caractéristiques de l apparei...

Reviews: