This type C appliance has an environmentally friendly sealed combustion chamber and air
supply circuit.
There are no restrictions concerning ventilation conditions and room dimensions.
The installation area must satisfy the maximum temperature values so as not to
impair the correct functioning of the boiler.
The boiler has been designed to be installed on a wall and cannot be installed on a base
or on the floor.
If the boiler is built-in, the minimum clearances that guarantee access to all boiler
components must be satisfied.
Dimensions and templates
1. Heating system return 3/4”
2. Cold water inlet ½”
3. Gas inlet 3/4”
4. Hot water outlet 1/2”
5. Heating system flow 3/4”
Minimum clearances
Comply with the minimum clearances indicated in the diagram to ensure easy and simple
maintenance operations.
Gas connections