background image

Installation and Operating Guide 

 

 

WhisperFlow® Portable Filtration System  

© 

Copyright 2021 Terra Universa

l Inc. All rights reserved. • Document No. 1788-48 

 

 

1.

 

Safety 

 

 

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

 

 

 

Do not use this unit for anything other than the intended manner of the manufacturer. Contact the manufacturer 

for additional clarification.  

 

Before  servicing  the  unit,  or replacing  a  filter,  switch  power  to  OFF  at  the  service  panel  and  lock  it  to  prevent 

accidental power activation. When the panel

 

cannot be locked, securely fasten a prominent warning device, such 

as a tag, to the service panel. 

 

Check the electronically communicated motor unit’s supply cord for damage, if it is damaged it must be replaced 

by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.  

 

Qualified person(s) must install the unit and configure the electrical wiring adhering to all applicable codes and 

standards, including fire-rated construction. 

 

If unit includes UV lamps, use UV radiation protective measures for personnel during service. Eye damage may 

result from direct exposure to the UV light.  

 

 

Critical Operation Conditions 

 

 

The filter media is extremely sensitive and can damage easily.  The screen only protects against an accidental 

‘touch’ of the filter media. Avoid touching and damaging the HEPA filter because the warranty will void. 

 

 

 Never place anything on the filter. Always place filter on its side to avoid damage.

 

 

Proprietary Notice

 

Safety Notice 

 

This manual pertains to proprietary devices manufactured by 
Terra Universal, Inc. Neither this document nor any portion of 
it may be reproduced in any way without prior written 
permission from Terra Universal.

 

A thorough familiarity with all operating guidelines is essential to safe operation of 
the product.  Failure to observe safety precautions could result in poor 
performance, damage to the system or other property, or serious bodily injury or 
death. The following symbols are intended to call your attention to two levels of 
hazard involved in operation.

 

 

 

Terra Universal makes no warranties applying to information 
contained  in  this  manual  or  its  suitability  for  any  implied  or 
inferred purpose.  Terra Universal shall not be held liable for 
any  errors  this  manual  contains  or  for  any  damages  that 
result from its use. 

 

 

CAUTION

 

Cautions are used when failure to observe instructions could result in 
significant damage to equipment.

 

 

 

 

WARNING

 

Warnings are used when failure to observe instructions or precautions 

could result in injury or death.

 

The information presented here is subject to change without notice.

 

CAUTION 

Summary of Contents for WhisperFlow

Page 1: ...de Document No 1788 48 WhisperFlow Portable HEPA Filtration System Copyright 2021 Terra Universal Inc All rights reserved Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Page 2: ...ersal Inc All rights reserved Document No 1788 48 2 Table of Contents 1 SAFETY 3 2 GENERAL INFORMATION 4 3 OPERATION 5 3 1 SPECIFICATIONS 6 3 2 FAN FILTER UNIT 6 4 MAINTENANCE 7 4 1 FILTER REPLACEMENT 7 5 TROUBLE SHOOTING 11 6 TESTING 11 7 REPLACEMENT ORDERS 12 8 REPLACEMENT PARTS 12 9 WARRANTY 13 ...

Page 3: ...sitive and can damage easily The screen only protects against an accidental touch of the filter media Avoid touching and damaging the HEPA filter because the warranty will void Never place anything on the filter Always place filter on its side to avoid damage Proprietary Notice Safety Notice This manual pertains to proprietary devices manufactured by Terra Universal Inc Neither this document nor a...

Page 4: ...n or exhaust For recirculation the HEPA filtered air will circulate in the confined areas for safe exhaust a flange adapter can be attached to the top of the unit for duct connection Air filtration systems are crucial in the fight against illnesses such s as SARS CoV 2 virus COVID 19 HEPA filters reduce the number of microscopic droplets and particles in the air that can carry pathogens to improve...

Page 5: ...drawn through intake grille at the bottom and purified air is discharged from the exhaust grille at the top to generate a sweeping low to high air circulation pattern to optimize clean breathing zone for patient and zone The filtration system s powerful blower can deliver 800 CFM to provide a large number or room air changes per hour to minimize the spread of airborne diseases to patients and heal...

Page 6: ...t Systems BMS to allow remote monitoring and control The EC motor offers high performance low energy consumption and low noise levels 40 dB with forward curved centrifugal fans These units comply with Title 24 and ErP 2015 Directive There are permanently lubricated bearings for long service life and a forward curved blower wheel that is factory balanced The FFU uses FDA approved Acrylic Urethane s...

Page 7: ...ow Portable Filtration System Copyright 2021 Terra Universal Inc All rights reserved Document No 1788 48 7 4 Maintenance 4 1 Filter Replacement Step 1 Remove the screws from the body and the back panel Step 2 Remove the back panel from the body ...

Page 8: ...e WhisperFlow Portable Filtration System Copyright 2021 Terra Universal Inc All rights reserved Document No 1788 48 8 Step 3 Remove the screws from the clip holding the fan filter unit in place Step 4 Remove the clip from the holder ...

Page 9: ...rating Guide WhisperFlow Portable Filtration System Copyright 2021 Terra Universal Inc All rights reserved Document No 1788 48 9 Step 5 Remove the FFU from the unit Step 6 Remove the screws from the FFU housing and filter ...

Page 10: ... and Operating Guide WhisperFlow Portable Filtration System Copyright 2021 Terra Universal Inc All rights reserved Document No 1788 48 10 Step 7 Remove the filter from the housing and replace it with the new filter ...

Page 11: ...if air velocity does not change High Air Velocity 1 Adjust the fan speed to a lower output 6 Testing WhisperFlow fan filter units are thoroughly tested at the factory before shipment All filters are tested with properly calibrated equipment to IEST RP 00034 and all filters are UL 900 recognized However because of the rigors of shipping Terra Universal encourages re test after installation Terra Un...

Page 12: ...ocated on the back of the unit Order Number _____________________________________________________________________________ Serial Number _____________________________________________________________________________ Unit Model Number _____________________________________________________________________________ Date _____________________________________________________________________________ 8 Repla...

Page 13: ...esponsible for filing and collecting a freight claim Any replacement products must be ordered and paid for separately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately u...

Reviews: