Conversion from right to left-side connection
The TERRA CL is pre-fitted with right-hand side connec
-
tion openings. The connection side can be changed if
required, however. The following steps are required to do
this:
Remove the panels on the right-hand side by unfastening
the eight screws.
Remove the central bar by unscrewing the two clamping
screws above and below.
Then remove the assembly angle above and below of the
profiles.
Converting the hydraulic pipework
1
3
2
4
The following steps need to be carried out to convert the
hydraulics:
Remove the right-hand side pipework and unfasten the
cable fittings.
Unfasten the connection angle with the crown nuts on
the plate heat exchanger. Turn the lower elbow joint by
180° and screw back on. Screw on the fixing clips and
threaded rods. Install the circulation pump and turn the
pump head back. Then screw on the pipe socket with
the pump beater and fit the fixing clip. With an electric
heating immerser, remove the brass extension piece so
that the connections are flush on the outside. Re-fasten
all connecting cables using the cable binder.
Then re-fit the panels onto the right-hand side.