background image

11

DVB-T bitrates (Mbit/s) for 

7 MHz

 bandwidth (non-hierarchical systems).

Modulation

Coding 

Rate

Guard Interval

1/4

1/8

1/16

1/32

QPSK

1/2

4.354

4.838

5.123

5.278

2/3

5.806

6.451

6.830

7.037

3/4

6.532

7.257

7.684

7.917

5/6

7.257

8.064

8.538

8.797

7/8

7.620

8.467

8.965

9.237

16-QAM

1/2

8.709

9.676

10.246

10.556

2/3

11.612

12.902

13.661

14.075

3/4

13.063

14.515

15.369

15.834

5/6

14.515

16.127

17.076

17.594

7/8

15.240

16.934

17.930

18.473

64-QAM

1/2

13.063

14.515

15.369

15.834

2/3

17.418

19.353

20.491

21.112

3/4

19.595

21.772

23.053

23.751

5/6

21.772

24.191

25.614

26.390

7/8

22.861

25.401

26.895

27.710

Summary of Contents for MHD101

Page 1: ...1 1 x HDMI to DVB T COFDM Home modulator MHD101 Operation Manual MHD101 manual v1 3 ...

Page 2: ...ntilation openings The ventilation should not be impeded by covering the ventilation openings with items such as newspapers table cloths curtains Mount the modulator in vertical position with RF connections underneath From top front and bottom of installed modulator must be at least 10 cm free space Installation Storage This unit contains high precision pieces of electronics To ensure optimal perf...

Page 3: ...l the internal parts in order to ensure that the device works normally In case of an internal error or module failure the MHD101 immediately initiates the recovery procedure by resetting the appropriate module or the device Finally watchdog timers ensure that the device will be reset in case of CPU failure 3 2 2 Buttons lock mechanism The MHD101 will lock the functionality of its buttons after 5 m...

Page 4: ...shed b Channel ON when Channel mode is selected c Attenuation ON when Attenuator mode is selected d Channel ON when Profile mode is selected 5 Ground connector 6 12 V DC power input 7 HDMI input 8 USB input 9 RF OUT output HDMI USB RF OUT Lock Attenuator Profile Channel 12V 0 34 Amax Channel Profile DVB T Full HD Modulator MHD101 MPEG 4 encoder AVC H 264 Output freq range 174 862 MHz Output level ...

Page 5: ...ected How Profiles works In an installation all the modulators or Mux in general need to have different values of the following fields to avoid conflicts in the automated scan of the TV sets Program Name Service ID TS ID For that reason the user must always selects a different Profile number in every modulator starting from Number 1 Eg Let s say we want to install three modulators in a CATV networ...

Page 6: ...arameters TS ID Original Network ID Network ID Provider Name LCN support Yes LCN Providers Nordin ITC UK EICTA Europe New Zealand DVB T Output Standard EN 300 744 Bandwidth 5 6 7 8 MHz Mode 2K 8K Constellation 16QAM 64QAM Guard Interval 1 4 1 8 1 16 1 32 Code Rate 1 2 2 3 3 4 5 6 7 8 RF Output Type RF DVB T COFDM Output Frequencies 174 862 MHz Output Level 90 dBμV max Connector 75Ω F female Output...

Page 7: ...mpanies the MHD101 System requirements Windows XP SP1 or higher Windows Vista Windows 7 32 64 bit Windows 8 32 64 bit Windows 10 32 64 bit Device connection via software 1 Insert the supplied software CD into your CD ROM drive 2 Connect the MHD101 via the USB cable A male to B male type 3 In case Windows cannot install the USB drivers automatically when prompt insert the correct path of the CD fol...

Page 8: ...N OFF Enables disables HDCP 3 Multiplexer settings In this category the user is able to adjust parameters of the MHD101 multiplexer as described below 3 1 Network Name ID Enter the Network name ID 3 2 Program Name ID Enter the Program name ID 3 3 Provider Name Enter the Provider name 3 4 Original Net ID Set the Net ID 0 65535 3 5 TS ID Set the Transport Stream ID 0 65535 3 6 PMT PID Set the PID va...

Page 9: ...ttings of this category are uploaded to the modulator The Factory Defaults button sets the modulator s setting to factory default The Reset System button applies a reset to the modulator This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usag...

Page 10: ...8 294 8 782 9 048 5 6 8 294 9 216 9 758 10 053 7 8 8 709 9 676 10 246 10 556 16 QAM 1 2 9 953 11 059 11 709 12 064 2 3 13 271 14 745 15 612 16 086 3 4 14 929 16 588 17 564 18 096 5 6 16 588 18 431 19 516 20 107 7 8 17 418 19 353 20 491 21 112 64 QAM 1 2 14 929 16 588 17 564 18 096 2 3 19 906 22 118 23 419 24 128 3 4 22 394 24 882 26 346 27 144 5 6 24 882 27 647 29 273 30 160 7 8 26 126 29 029 30 7...

Page 11: ...57 7 684 7 917 5 6 7 257 8 064 8 538 8 797 7 8 7 620 8 467 8 965 9 237 16 QAM 1 2 8 709 9 676 10 246 10 556 2 3 11 612 12 902 13 661 14 075 3 4 13 063 14 515 15 369 15 834 5 6 14 515 16 127 17 076 17 594 7 8 15 240 16 934 17 930 18 473 64 QAM 1 2 13 063 14 515 15 369 15 834 2 3 17 418 19 353 20 491 21 112 3 4 19 595 21 772 23 053 23 751 5 6 21 772 24 191 25 614 26 390 7 8 22 861 25 401 26 895 27 7...

Page 12: ... QPSK 1 2 3 732 4 147 4 391 4 524 2 3 4 976 5 529 5 855 6 032 3 4 5 599 6 221 6 587 6 786 5 6 6 221 6 912 7 318 7 540 7 8 6 532 7 257 7 684 7 917 16 QAM 1 2 7 465 8 294 8 782 9 048 2 3 9 953 11 059 11 709 12 064 3 4 11 197 12 441 13 173 13 572 5 6 12 441 13 824 14 637 15 080 7 8 13 063 14 515 15 369 15 834 64 QAM 1 2 11 197 12 441 13 193 13 572 2 3 14 929 16 588 17 564 18 096 3 4 16 796 18 662 19 ...

Reviews: