background image

PRODUCT  DESСRIPTION

TV modulator MT32 is intended to form TV channels of B/G/D/K/Au/I/L/standards in VHF and UHF ranges.

TV modulator MT32C is intended to form TV channels of B/G/D/K/Au STEREO A2/DUAL/MONO and I/L MONO standards 

in VHF and UHF ranges.

Broadcasting signal has vestigial sideband modulation.

The housing of modulators meets more stringent screening requirements according to EN50083-2, class A.

The modulators are intended for indoor use only. Suitable for moderate and tropical climates.

SAFETY  INSTRUCTIONS

Installation of the modulator must be done according IEC60728-11 and national safety standards.

The modulator is powered from mains 230V~. This voltage is dangerous to life. 

Any repairs must be done by a qualified personnel. 

To avoid the electric shock follow these instructions: 

do not remove the cover of the power supply section, without disconnecting the unit from the mains supply;

do not plug the modulator into the mains supply if the power cord or plug are damaged;

do not plug the modulator into the mains supply until all cables have been connected correctly;

to disconnect the modulator from the mains completely, disconnect plug from the mains socket;

the mains socket must be easily accessible;

modulator shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall be 

placed on it;

avoid placing modulator next to central heating components and in areas of high humidity;

before connecting the modulator to multimedia system, be sure that system is installed in accordance to national safety 

standards;

devices of multimedia system should have easy access to disconnect them from the mains supply;

no naked flame sources, such as lighted candles, should be placed on modulator;

if the modulator has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before 

plugging into the mains;

do not insert any objects into ventilation openings;

the ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, 

curtains;

mount the modulator in vertical position with power supply located on the top; modulator

 must be fixed with steel screws 

Ø 4-5 mm. The screws are not included in a package.

from top, front and bottom of installed modulator must be at least 10 cm free space.

EXTERNAL VIEW  AND OPERATING CONTROLS

TV MODULATORS  MT32, MT32C

TERRA UAB, 

Draugystes str. 22, LT-51256 Kaunas, Lithuania, Tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 

E-mail: sales@terraelectronics.com, http://www.terraelectronics.com

-

 VIDEO

 - video signal input connector (RCA type)

-

 

AUDIO L

 - audio left channel signal input connector 

     (RCA type)

-

 

AUDIO R

 - audio right channel signal input connector 

     (RCA type)

-

 RF IN 

 - RF signal input connector (F type)

-

 RF OUT

  - RF signal output connector (F type) 

6

 - 

AUDIO

 - sound subcarrier deviation regulator 

      (for MT32 only)

-

 RF LEVEL

 - RF output signal level regulator

-

 

two-digit LED display

-

 

control buttons

10

 - power cord

11

 - functional grounding clamp

12

 - screwdriver

Figure 1. External view of the modulator

Vers. 1.02

1

2

3

4

5 11

7

6

8

9

10

12

Summary of Contents for MT32

Page 1: ...ity before connecting the modulator to multimedia system be sure that system is installed in accordance to national safety standards devices of multimedia system should have easy access to disconnect them from the mains supply no naked flame sources such as lighted candles should be placed on modulator if the modulator has been kept in cold conditions for a long time keep it in a warm room no less...

Page 2: ...change parameter by pressing button and set necessary mode by pressing button 1 TV system setting a after switching settings mode indicator displays current TV system see table 1 b set necessary TV system by pressing button see tables 2 8 c after TV system changing modulator sets to first channel of selected TV system see tables 2 9 other settings remains unchanged 2 test pattern generator a press...

Page 3: ...uct complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usage only Equipment is double insulated from the mains with functional earthing Functional earthing Connect to the main potential equalization TERRA confirms that this product is in accordance to fol...

Page 4: ...аналов стандартыB G D K Аu I L вметровоми дециметровом диапазонах Модулятор MT32C предназначен для формирования ТВ каналов со стерео звуком стандарты B G D K Аu стерео A2 дуал моно и I L моно в метровом и дециметровом диапазонах Транслируемый сигнал имеет одну боковую полосу Корпус модуляторов соответствует более жестким требованиям по экранированию согласно EN50083 2 класс A Модуляторы предназнач...

Page 5: ...лязащитымодуляторовотнесанкционированногодоступанеобходимодваждывтечении 0 5сек одновременнонажать кнопки и Символ LO появится коротко Для отключения защиты необходимо повторить выше указанные действия Символ UL появится коротко Символ LO появится на экране в случае если управление модулятором заблокировано УСТАНОВКА ДЕВИАЦИИ ПОДНЕСУЩЕЙ ЗВУКОВОГО СИГНАЛА MT32 С помощью регулятора рис 1 поз 6 возмо...

Page 6: ...S25 343 25 349 75 26 S26 351 25 357 75 27 S27 359 25 365 75 28 S28 367 25 373 75 29 S29 375 25 381 75 30 S30 383 25 389 75 31 S31 391 25 397 75 32 S32 399 25 405 75 33 S33 407 25 413 75 34 S34 415 25 421 75 35 S35 423 25 429 75 36 S36 431 25 437 75 37 S37 439 25 445 75 38 S38 447 25 453 75 39 S39 455 25 461 75 40 S40 463 25 469 75 SYSTEM B G b5 Band Displayed Channel Vision C Audio C 01 E1 45 25 5...

Reviews: