"QQFOEJY
.*%*JNQMFNFOUBUJPOBOE$IBSUT
*OTUBMMBUJPO*OUSPEVDUJPO.*%*
EJHJUBM9UFOTJPONJDSP8"7&1$
2.64 DISL
***************************************************
DISL 45h LCD Recall
Upon receprion of a Display Recall message, the LCD
and the LEDs will be updated in order to discard a
possibly previously dumped LCD content.
The full format of a DISL Dump is:
Index Label Value Description
---------------------------------------------------
0 EXC F0h Marks Start of SysEx
1 IDW 3Eh Waldorf Electronics
GmbH ID
2 IDE 0Eh Microwave 2 ID
3 DEV Device ID
4 IDM 45h here DISL (LCD Recall)
5 XSUM 0 Checksum
6 EOX F7h End of SysEx
---------------------------------------------------
***************************************************
2.71 RMTP
***************************************************
RMTP 26h Remote Control Parameter Change
The remote control Parameter change is used to
remotely control the encoders and buttons of the
Microwave 2. Operation might still introduce bugs.
The Element to move is coded in one byte:
UU Element
------------------------------------------------
00 Encoder #1 (left)
01 Encoder #2
02 Encoder #3
03 Encoder #4
04 Encoder #5 (big red one)
05 Play/Shift button
06 Soundpar #1/Store button
07 Soundpar #2/Recall button
08 Soundpar #3/Compare button
09 Multipar/Undo button
0A Global/Utility button
0B Power button
------------------------------------------------
Annother byte defines the movement to be simulated:
MM Encoder Button
------------------------------------------------
00 encoder left turn -64 released
01 encoder left turn -63 pressed
2-63 encoder left by MM pressed
64 no encoder move pressed
65 encoder right by one pressed
66-127 encoder right by MM pressed
------------------------------------------------
The full format of a RMTP Dump is:
Index Label Value Description
---------------------------------------------------
0 EXC F0h Marks Start of SysEx
1 IDW 3Eh Waldorf Electronics
GmbH ID
2 IDE 0Eh Microwave 2 ID
3 DEV Device ID
4 IDM 26h here RMTP
5 UU see text Element
6 MM see text Simulated movement
7 XSUM (UU+MM)&7Fh Checksum
8 EOX F7h End od SysEx
----------------------------------------------------
****************************************************
2.81 MODR
***************************************************
MODR 07h Mode Request
The full format of a MODR Dump is:
Index Label Value Description
---------------------------------------------------
0 EXC F0h Marks Start of SysEx
1 IDW 3Eh Waldorf Electronics
GmbH ID
2 IDE 0Eh Microwave 2 ID
3 DEV Device ID
4 IDM 07h here MODR
5 EOX F7h End of SysEx
---------------------------------------------------
***************************************************
2.82 MODD
***************************************************
MODD 17h Mode Dump
The full format of a MODD Dump is:
Index Label Value Description
---------------------------------------------------
0 EXC F0h Marks Start of SysEx
1 IDW 3Eh Waldorf Electronics
GmbH ID
2 IDE 0Eh Microwave 2 ID
3 DEV Device ID
4 IDM 17h here MODD
5 Mode 0-1 0: Sound 1:Multi
6 EOX F7h End of SysEx
---------------------------------------------------
**************************************************