Introduction
134
RangePro RPX8-P User Manual
P • Using the D400 Charger with a RangePro RPX8-P Battery
Introduction
The Range Pro X8 RP6S24KHDx is a dual 6S2P, 24,000 mAh, high density, battery pack consisting of two
independent 6S2P Lithium Ion Polymer battery packs installed in a single battery cage. The battery packs are
impedance matched at the factory, placed in a common cage, and wired independently to a single connector.
On the aircraft the unit provides a blind mating power solution with easy insertion and extraction from the sys-
tem using a dovetail rail system and latching mechanism. The power pins from both battery packs, though
housed in the same connector, are independently routed to the aircraft power sensor module.
For charging, power and balance port connectors are separately wired for each battery pack and broken out for
connection to a charger using a custom cable. To connect the RP6S24KHDx to the SKYRC Ultimate Duo
400W (D400) Balance Charger, use the RPBCCA400-12 twelve-inch cable that includes a battery mating con-
nector on one end and two sets of power and balance ports on the other. Custom cable lengths are available
upon request.
This appendix provides instructions on how to customize the D400 charger for use with the RP6S24KHDx
battery as well as some common troubleshooting steps for addressing issues that may arise when the unit is not
set up correctly. For additional details on how to use the D400, refer to the Ultimate Duo Instruction Manual
provided with the charger.
Modify and Verify System Settings
Verify the correct system settings for BOTH charging channels using the following steps:
1.
Power-on the Ultimate Duo 400W Charger (D400).
2.
Press the
STATUS
“
+
” or “
-
” buttons for the channel until the display screen reads:
BATT/PROGRAM
SYSTEM SETTING->
3.
Press
ENTER
“
” to review the system settings.
4.
To scroll from one parameter to another, use the
STATUS
“
+
” or “
-
” buttons.
5.
To change the value of a parameter enter into editing mode by pressing
ENTER
“
”.
6.
In editing mode, the value of the selected parameter will blink slowly. Press the
STATUS
“
+
” or “
-
” button
to adjust the parameter value. When the value is set correctly exit the editing mode by pressing the
ENTER
“
” button. Some screens contain two parameters. In this case, pressing the
ENTER
“
” button will
close editing for the first parameter and open editing for the second parameter.
ENTER
“
” a second time
will close editing on the second parameter.
Summary of Contents for RangePro RPX8-P
Page 90: ...90 Chapter 12 Contacting TerraView for Support Chapter Contents Support Options 91...
Page 104: ...104 Appendix F LED Meanings Chapter Contents Introduction 105...
Page 119: ...119 Appendix K Configuration Specific Parameters Chapter Contents Load Specific Parameters 120...
Page 121: ...121 Appendix L Making Sense of Motor Tests Chapter Contents Making Sense of Motor Tests 122...
Page 123: ...123 Appendix M Serial Port Assignment Chapter Contents Serial Port Assignment 124...