Balance Charge the Battery Using Battery Memory #1
136
RangePro RPX8-P User Manual
P • Using the D400 Charger with a RangePro RPX8-P Battery
6.
To scroll from one parameter to another, use the
STATUS
“
+
” or “
-
” buttons.
7.
To change the value of a parameter enter into editing mode by pressing
ENTER
“
”.
8.
In editing mode, the value of the selected parameter will blink slowly. Press the
STATUS
“
+
” or “
-
” button
to adjust the parameter value. When the value is set correctly exit the editing mode by pressing the
ENTER
“
” button.
9.
When all system settings for the channel have been properly set and verified it is necessary to save the pro-
grammed values. The last option in the parameter list is “
SAVE PROGRAM
”. To save the program press
the
ENTER
“
” button. On the screen the word “
ENTER
” will disappear and be replaced with the word
"
SAVE…."
When these memory settings have been saved the display screen will return to the Battery
Memory screen and alternate between the following.
[BATT MEMORY 1]
[BATT MEMORY 1]
LiHV 22.8V(6S)
C:6.0A D:3.0A
10.
Press the
BATT/PROG
“ ” button to return to the main menu.
11.
If not already completed, repeat steps 2 through 10 for the other charging channel.
Balance Charge the Battery Using Battery Memory #1
1.
Start up the Ultimate Duo 400W Charger (D400)
2.
Press the
STATUS
“
+
” or “
-
” buttons for the channel until the display screen reads:
BATT/PROGRAM
BATT MEMORY
3.
Press
ENTER
“
” to gain access to the ten (10) battery memory locations.
Parameter
Channel 1 Value(s)
Channel 2 Value(s)
BATT TYPE
LiHV
LiHV
BATT VOLTAGE
22.8V(6S)OFF
22.8V(6S)OFF
CHARGE CURRENT
6.0A
6.0A
DSCHG CURRENT
3.0A
3.0A
DSCHG VOLTAGE
3.2V/CELL
3.2V/CELL
TVC=YOUR RISK!
4.30V
4.30V
SAVE PROGRAM
(see below)
(see below)
Anytime the BATT TYPE is changed and the program saved, the TVC (Terminal Voltage
Charge) is reset to the default voltage for that battery type and will remain at the default
value until manually changed by the user.
Prior to saving the program always confirm
the TVC is set to the correct value!
IMPORTANT
Summary of Contents for RangePro RPX8-P
Page 90: ...90 Chapter 12 Contacting TerraView for Support Chapter Contents Support Options 91...
Page 104: ...104 Appendix F LED Meanings Chapter Contents Introduction 105...
Page 119: ...119 Appendix K Configuration Specific Parameters Chapter Contents Load Specific Parameters 120...
Page 121: ...121 Appendix L Making Sense of Motor Tests Chapter Contents Making Sense of Motor Tests 122...
Page 123: ...123 Appendix M Serial Port Assignment Chapter Contents Serial Port Assignment 124...