Battery Installation
45
RangePro RPX8-P User Manual
5 • Assemble RangePro RPX8-P for Flight
Figure 21. Battery tester connected to battery
Figure 22. Cable B1 connector black wire
7.
Repeat steps 3 through 6 to plug connector B2 into the battery tester, and verify that all battery cells are at
least 4.2 V.
DO NOT
fly the RangePro RPX8-P if the variation between cells exceeds 0.1 volts. Bal-
ance charging the battery typically results in all cells being within 0.03 volts of each
other. If the variation between cells exceeds 0.1 volts this may be an indicator of a failing
battery.
DO NOT
attempt to fly the RangePro RPX8-P if the total battery voltage is below 19.2
volts (3.2 volts per cell).
If the battery voltage is too low, or is reporting variation between cells in excess of 0.1
volts, refer to section
on page 84 to charge the battery.