NOTE 
 
All electrical connections should be made by a licensed electrician.  All local and National 
codes should be followed as applicable. 
 

Circuit Requirements 
 

The TWSD16128PHC should be connected to a 120V, 15A feeder circuit. 
The maximum capacity of the power receptacle in the unit is 120V, 12A. 
 
The circuit breaker of the feeder circuit is considered to be the disconnect device for 
TWSD16128PHC.  Therefore, this circuit breaker should be readily accessible. 
The strain relief (liquid tight cord connector) is suitable for flexible cord with a diameter of 
10mm.  We recommend using S-W or S-J cord, minimum 16 AWG. 
 

WARNING

 – TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT SUPPLY 

MAINS BEFORE SERVICING. 
 
The supply line used to feed power to the feeder circuit should be rated for outdoor use.  
Refer to the NEC and local codes as applicable. 
 

WARNING

:  To prevent the risk of electric shock and equipment damage, disconnect any 

and all power supply to the enclosure before installing, maintaining or trouble shooting this 
product or any products inside the enclosure.   
 

 

 
Electrical Connection 
 
Before running electrical power to the device, you must first install the cord gland bushing 
that comes included with the enclosure.  Be sure the install the cord gland bushing with the 
gasket of the outside of the enclosure.  Also, the cord gland bushing nut should be tightened 
snugly by hand.  Once the bushing has been tightened by hand then use a wrench to apply 
an additional quarter turn for final tightening.  Do not over tighten the nut – over tightening the 
nut can result in the cracking of the cord gland bushing. Refer to figure 8. 
 
The electrical wiring should be routed through the cord gland bushing to the terminal block.  
Refer to wiring diagram – figure 5. 
 
 
 

Summary of Contents for TWSD16128PHC

Page 1: ...10521 Gulfdale San Antonio TX 78216 I www terrawave com I Email sales terrawave com I Phone 210 375 8482 Version 1 1 Page 1 Installation Instructions TWSD16128PHC...

Page 2: ...always be followed to reduce the risk of electric shock fire and injury to persons including the following All wiring that connects to this equipment must meet applicable local and national building...

Page 3: ...es not operate normally when following the operating instructions The TWSD16128PHC has been damaged The TWSD16128PHC exhibits a distinct change in performance Heater FAN The TWSD16128PHC includes a he...

Page 4: ...ailure of the unit Figure 6 WARNING To prevent the risk of electric shock and equipment damage disconnect any and all power supplies to the enclosure before installing maintaining or trouble shooting...

Page 5: ...lling WLAN Networking Components The TWSD16128PHC will accommodate WLAN Networking products to be installed inside the unit This equipment should be installed on the mounting plate in the unit Wire Ca...

Page 6: ...the unit Once the Fly nut has been removed the plug will fall out of the enclosure Replace the plug with conduit The conduit must be suitable for environmental and wet locations Refer the NEC and foll...

Page 7: ...5 10 563 0 313 12 563 0 313 Terminal Block C D D B B C B B I I E F G H H J J J J D D Nothing higher than 4 from bottom 0 25 3 125 3 375 3 875 4 125 4 625 5 75 5 875 6 375 6 875 2 687 3 312 3 375 3 437...

Page 8: ...Customer Provided WLAN Networking Mounting Screws Qty Description 4 10 32 x 3 8 counter sunk Philips head 4 8 32 x 3 8 round Philips head 2 6 32 x 3 8 round Philips head 1 10 32 locking post TerraWav...

Page 9: ...ther structure using customer supplied 3 8 inch fasteners flat washers and nuts To insure that the unit maintains proper sealing it is very important to make sure that the fasteners washer and nuts ar...

Page 10: ...he supply line used to feed power to the feeder circuit should be rated for outdoor use Refer to the NEC and local codes as applicable WARNING To prevent the risk of electric shock and equipment damag...

Page 11: ...I Email sales terrawave com I Phone 210 375 8482 Version 1 1 Page 11 Figure 8 Cord Gland Bushing nut on inside of enclosure DO NOT OVER TIGHTEN Cord Gland Bushing on outside of enclosure Ensure that...

Page 12: ...power leads that are wired to the terminal block inside the TWSD16128PHC The wiring should be applied as follows 1 The Black wire in figure 5 represents the hot lead and should be attached to the term...

Reviews: