background image

FF-MM-370-REV - 01

Page 15

Operation and Maintenance Guide  6 VM Air Motor Series

EU DECLARATION OF CONFORMITY

Object of declaration

PRODUCT  

 

 

PNEUMATIC VANE MOTOR

  

MODEL 

   : 6VM 

XXXXX, 

MANUFACTURER’S NAME   

TERYAIR EQUIPMENT PVT. LTD.

ADDRESS 

 

 

SITE - 1: BUILDING A - 1/2, 102 TO 105 & BUILDING C 12 & 13,    

 

 

 

 

 

TIRUPATI UDYOG NAGAR, SATIVALI ROAD, VASAI (E),   

 

     PALGHAR 

401208.

 

 

 

 

 

SITE - 2: AUGUSTINE - II, COLACO INDUSTRIAL COMPLEX, GALA NO  

 

  

 

 

 

101 TO 107, SATIVALI ROAD, VILLAGE WALIV, VASAI (E), PALGHAR:  

  

    401208

To provide presumption of conformity in order to directive 2014/34/EU; the following harmonized standards and/or other 

normative documents as referenced within the following official journals are applied:

APPLICABLE DIRECTIVE: ATEX DIRECTIVE (2014/34/EU)

APPLICABE STANDARDS

:

 

EN ISO 80079-36: 2016

  : 

Explosive atmospheres —Part 36: Non-electrical equipment for explosive atmospheres  

    Basic 

method 

and 

requirements.

EN ISO 80079-37:2016

  : 

Explosive atmospheres —Part 37: Non-electrical equipment for explosive atmospheres  

 

 

 

 

Non- electrical type of protection constructional safety ‘c’, control of ignition sources ‘b’,  

    liquid 

immersion 

‘k’.

Notified body to whom Technical file has logged with: - Technicka Inspekcia (Ref: 1354).

DECLARATION: - TERYAIR EQUIPMENT PVT. LTD.,

 declare that under our sole responsibility for the supply of the 

product defined above, the said product complies with all the applicable Directives, Regulations and all essential Health and 

Safety requirements applying to it.

I, the undersigned, hereby declare that the product specified above conforms to the above standard(s).

ATEX MARKING APPLIED

:                   ll 2 GD Ex h IIC T6 Gb

                        

 

     

                       Ex h IIIC T85oC Db

                                

Signed for and on behalf of

TERYAIR EQUIPMENT PVT. LTD. 

 

 

 

Place of Issue:

        Date:

Summary of Contents for 6VMD Series

Page 1: ...VMNXXX NEMA Model with Lube Lube Free SG Iron SS NPT BSPT Variants 6VMDXXX IEC Model with Lube Lube Free SG Iron SS NPT BSPT Variants 6 V M Read this manual carefully before installing operating or se...

Page 2: ...tructions 6 Operating instructions 7 Suggested Lubricants 7 Troubleshooting 8 Dis assembly and Re assembly 9 Exploded View for 6VM Air Motor 10 Bill of Materials for 6VM Series SG Iron 11 Bill of Mate...

Page 3: ...12 Nm 105 lbs in Air Consumption 0 to 240 m3 hr 0 to 140 cfm Motor Weight 7 5 kgs 16 5 lbs Operating Pressure 1 4 to 7kg cm2 20 to 100PSI Max Allowable speed 3500 rpm ATEX limit 500 2500 2000 1000 15...

Page 4: ...or on the casting opposite the pipe ports The maximum surface temperature listed on the motor is for nor mal environmental and installation conditions Fort air motors Temp Class T6 Gas and T85 C Dust...

Page 5: ...inches 1 2 meter from the air motor Install the lubricator level with or above the air motor so that the oil mist will blow direct ly into or fall down into the motor Install a ilter in the air line b...

Page 6: ...e Check the direction of the motor airflow A single rotation motor will operate properly only in one direction Single rotation motors require a muffler to be connected to the air port Remove the plast...

Page 7: ...or serviced Air source inadequate Inspect and repair Air source too far from motor Reconfigure setup Suggested Lubricants Brand Above 27 Deg C From 5 Deg C to 27 Deg C Below 5 Deg C Shell Toona R 72 T...

Page 8: ...e To remove the Front Bearing Cap 6 from Front Flange 2 unscrew CSK Bolt 21 from it The O ring 9 and Oil Seal 10 can be now removed from Front Bearing Cap 6 Replace with new ones if found damaged f N...

Page 9: ...REV 01 Page 9 Operation and Maintenance Guide 6 VM Air Motor Series Exploded View for 6VM Air Motor 1 13 17 4 3 7 9 5 19 11 14 18 24 23 16 20 15 12 2 6 9 10 21 FOOT FACE 25 7 18 14 22 10 8 2 IEC NEMA...

Page 10: ...1 1 1 1 1 1 1 6 FRONT BEARING CAP 805 21 11 1 1 1 1 7 BALL BEARING 2Z ZZ 805 50 02 2 2 2 2 1 1 1 1 8 BALL BEARING 2Z ZZ 805 50 01 1 1 1 1 9 O RING 805 40 01 2 2 2 2 1 1 1 1 10 OIL SEAL 805 60 01 1 1...

Page 11: ...03 1 1 5 REAR BEARING CAP 805 27 04 1 1 1 1 1 1 1 1 6 FRONT BEARING CAP 805 27 05 1 1 1 1 7 BALL BEARING 2Z ZZ 805 50 02 2 2 2 2 1 1 1 1 8 BALL BEARING 2Z ZZ 805 50 01 1 1 1 1 9 O RING 805 40 01V 2 2...

Page 12: ...FF MM 370 REV 01 Page 12 Operation and Maintenance Guide 6 VM Air Motor Series Foot Mounting 6VM FACE Mounting 6VM Dimensional Data...

Page 13: ...FF MM 370 REV 01 Page 13 Operation and Maintenance Guide 6 VM Air Motor Series NEMA Flange Mounting 6VM IEC Flange Mounting 6VM...

Page 14: ...CRIPTION S NO We Hereby Certify That The Above Referenced Product Has Tested And Inspected In Accordance With Our Standard Test Pro cedures And Meets The Specifications For Material And Performance Va...

Page 15: ...EN ISO 80079 36 2016 Explosive atmospheres Part 36 Non electrical equipment for explosive atmospheres Basic method and requirements EN ISO 80079 37 2016 Explosive atmospheres Part 37 Non electrical e...

Page 16: ...after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance with T...

Page 17: ...FF MM 370 REV 01 Page 17 Operation and Maintenance Guide 6 VM Air Motor Series This page is intentionally Left blank...

Reviews: